AKD PDMM User Guide | 15.1 Fault and Warning Messages
Fault
Message/Warning
Cause
Remedy
n170 Customer profile table is not
initialized.
This warning appears with
n160. This warning is triggered
when you try to trigger a
motion task that uses a cus-
tomer profile table for gen-
erating the velocity profile and
when the selected profile table
is empty (see MT.CNTL and
MT.TNUM.
Change the MT.TNUM param-
eter for this specific motion task
in order to use an initialized pro-
file table. Activation of any new
motion or using of
DRV.CLRFAULTS will clear the
warning.
F201
Internal RAM failed.
Hardware failure detected.
Restart drive. If issue persists,
contact technical support.
F202
External RAM failed.
Hardware failure detected.
Restart drive. If issue persists,
contact technical support.
F203
Code integrity failed.
Software failure detected.
FPGA register access failure
occurred.
Restart drive. If issue persists,
contact technical support.
F245
External fault.
This fault is user generated
and is caused by user set-
tings.
Users can configure a digital
input to trigger this fault
(DINx.MODE = 10). The fault
occurs according to this input
setting. Clear the input to clear
the fault.
F247 Bus voltage exceed allowed
thresholds.
Hardware problem in bus
measurement.
Troubleshoot and repair hard-
ware problem.
F248 Option board EEPROM cor-
rupted.
EEPROM failure detected.
Restart drive. If issue persists,
exchange drive.
F249 Option board downstream
checksum.
Communications with the I/O
on the option board failed.
DRV.CLRFAULTS. If issue per-
sists If issue persists, contact
technical support.
F250 Option board upstream check-
sum.
Communications with the I/O
on the option board failed.
DRV.CLRFAULTS. If issue per-
sists If issue persists, contact
technical support.
F251 Option board watchdog.
Communications with the I/O
on the option board failed.
DRV.CLRFAULTS. If issue per-
sists If issue persists, contact
technical support.
F252 Firmware and option board
FPGA types are not com-
patible.
The option board FPGA is not
compatible with this hardware.
Download the correct firmware
file for this drive.
F253 Firmware and option board
FPGA versions are not com-
patible.
The version of the option board
FPGA is not compatible with
this firmware.
Download the correct firmware
file for this drive.
F301
n301
Motor overheated.
Motor overheated.
Check ambient temperature.
Check motor mounting heat
sink capability
F302
Over speed.
Motor exceeded VL.THRESH
value.
Increase VL.THRESH or lower
velocity command.
Kollmorgen™ | December 2012
140
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...