Choosing “<User Defined>” allows you to record data from pre-defined locations. These locations are pro-
vided by the factory to collect less common values.
13.2.1.2 Color Column
For valid sources, you can click on the color in the Color tab and choose a different color than the default,
or create a custom color.
13.2.1.3 Hide Column
You can check the
Hide
box to hide a given plot trace. This feature can make it easier to focus on specific
data as needed.
13.2.1.4 Y-Axis Column
The Y-axis column allows you to choose on which Y-axis the channel will be displayed. Several prede-
fined Y-axis groups exists. Click on the item in the column to change the label for the trace.
13.2.1.5 Filter and Filter Frequency Column
Check this box and use the frequency column to apply a low pass filter to the data collected. The filter is
applied when the data is collected. It is not applied to data already collected if this is checked after the
data is collected.
13.2.2 Scope Time-base and Trigger Tab
Use the
Time-base and Trigger
tab to select how much data to record and when to start (trigger) record-
ing the data. You can set length of recording in ms and the sampling frequency in Hz. The number of sam-
ples is a calculated value displayed for reference.The trigger can be set to trigger immediately when you
click
Start Recording
or to trigger when a specified value for a given signal is reached. The default
Time-
base and Trigger
view specifies recording time, sampling frequency, and either an immediate trigger or a
trigger based on a specified signal. Click the
More
button in this view to specify a given number of sam-
ples, sampling frequency, sampling interval, and access additional trigger options.
104
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...