Kolin KAG-100WCINV Owner'S Manual Download Page 1

air conditioner

works

for

years

OWNER’S MANUAL

www.kolinphil.com.ph

Thank you for choosing our air conditioner.  Please read this owner’s 
manual before operation and retain it for future reference.  If you have lost 
this manual, please contact our nearest service center or visit our website.

WINDOW TYPE AIR CONDITIONER

FULL DC

INVERTER

s e r i e s

Summary of Contents for KAG-100WCINV

Page 1: ...k you for choosing our air conditioner Please read this owner s manual before operation and retain it for future reference If you have lost this manual please contact our nearest service center or vis...

Page 2: ...KAG 250WCINV KAG 200WCINV KAG 145WCINV KAG 100WCINV KAG 75WCINV MODELS...

Page 3: ...nt Remote control panel Operation Tips Thank you for choosing our air conditioner Our design is based on the best e ciency lowest noise operation and keeping the room more comfortable Please read this...

Page 4: ...peci cation Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the sup...

Page 5: ...ty then no electrical supply shall be connected to the circuit until it is and component inspection procedures If a fault exists that could compromise Repair and maintenance to electrical components s...

Page 6: ...nted 4 3 7 3 4 3 1 2 8 2 6 2 3 2 1 1 8 1 6 1 4 1 3 1 1 ceiling mounted table Minimum room area m2 3 Leak test is a must after installation room area 2 The air conditioner must be installed in a room t...

Page 7: ...epartment for assistance Relation to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks sh...

Page 8: ...therwise it may Please contact your nearest authorized service center to repair your air conditioner Do not repair the air conditioner by yourself It may cause electric shock or damage cause electric...

Page 9: ...ection Summer Cooling in summer Dehumidifying in rainy or humid season In hot summer Air conditioner can cool down the room air by transferring the heat out Without reducing the room temp air conditio...

Page 10: ...ough space components not work easily cause the compressor and electric which may damage the refrigerant system and too low the compressor will vibrate violently when the voltage is too high If the vo...

Page 11: ...om thermal springs and polluted by sulphurous gas or any special areas please contact the seller before using Otherwise will not be responsible for the possible damage on the unit Service Center near...

Page 12: ...mandatory fixed on the building shown at the right not iron support bracket has to be used enough to support the air conditioner if figure Using an iron support bracket is outdoors then the iron supp...

Page 13: ...rom the cabinet 2 Install the drain pan to the corner of the cabinet with 2 screws 3 Connect the drain hose to the outlet on the drain pan bottom 4 Slide the chassis into its original place in the cab...

Page 14: ...t Then it must be done under Before relocating the air conditioner you should Relocate Please use the safety support Please contact the seller as soon as there is strange noise during operation Be sur...

Page 15: ...Front intake grille behind the front intake grille Panel outlook picture just for reference please take the real unit as standard Horizontal Louver upwards downwards or straight out positioning manua...

Page 16: ...3 4 Swing button 5 Fan button 6 Sleep button 7 Timer button 8 Health button 9 WiFi button 2 4 7 9 8 6 5 3 1 button Note This is a general use remote controller for air conditioners For some function...

Page 17: ...an button Press this button to turn ON OFF swing 4 Swing button increase or decrease by 0 5h 30 minutes Hold the or button 2s then later the time displayed by 1 F C Pressing or button once will increa...

Page 18: ...being energized Under switch on or switch o state you may hold and FAN buttons Light function erature display between C and F Under OFF status press and Mode buttons simultaneously to switch temp Tem...

Page 19: ...over of battery box along the arrow direction 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box battery signal sende...

Page 20: ...is from 16 30 Timer can be set by pressing button Timer can be set in 0 5hour increments between 1 and 10 hours or in 1 hour increments for 10 hours or above after each push on or button This feature...

Page 21: ...hen the air co nditioner is in operation Keep the room temp uniform Adjust the vertical and horizo a uniform temperature in the room Air can t be discharged to the direction of air in Make sure that t...

Page 22: ...e air co nditioner s plastic parts will melt if exposed to excessive heat Avoid exposing the body dire ctly to a continuous unidirect ional air flow for long periods This is not recommended for health...

Page 23: ...g cooling Inappropriate treatment of the unit involves the risk of severe damages of people and material Details to this refrigerant are found in chapter refrigerant of Safety Operation of flammable R...

Page 24: ...cleaning Plug out only after air con ditioner stops at all 4 Dry the cloth by hands be fore cleaning Accident could happen Do not splash water directly into the unit in which there are micro computer...

Page 25: ...or repair it saves your time and money the air conditioner unit Is the air inlet or outlet blocked room This is the sound of the dehumidifying water being processed inside the air conditioner unit the...

Page 26: ...eal with it Please contact professional person to deal with it Please contact professional person to deal with it LP Please contact professional person to deal with it Fo Please contact professional p...

Page 27: ...all be General work area the risk of a ammable gas vapour being present while the work is being performed Work shall be undertaken under a controlled procedure so as to minimize Work procedure prior t...

Page 28: ...or the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a...

Page 29: ...s only with parts speci ed by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak 9 Cabling Check that cabling will not be subject to wear corrosion ex...

Page 30: ...3 there is ventilation available Ensure that the outlet for the vacuum pump is not close to any ignition sources and operation is absolutely vital if brazing operations on the pipe work are to take pl...

Page 31: ...nt The label shall be dated and signed Ensure that here are labels on the equipment stating the equipment contains ammable refrigerant 16 Recovery When removing refrigerant from a system either for se...

Page 32: ...ils are to be removed ensure that they have been evacuated to an acceptable level to make certain that ammable refrigerant does not remain within the lubricant The evacuation process shall be carried...

Page 33: ...ity 082 227 7063 Iloilo Door 4 TDK Realty Development Corporation Building South Fundedor St Barangay Fundedor Molo Iloilo City 033 336 1970 Pampanga Mexico Gold Commercial and Residential Building Jo...