6
KOLDWAVE 3AK (AIRMASTER)
DISCHARGE AIR GRILL
The Koldwave Airmaster is equipped with one 16
x 12.5 plastic grille, located in the upper front
panel, to provide a cool and quiet air flow.
AIR FILTERS
The Koldwave Airmaster employs three, 1/2"
thick, washable, aluminum mesh (black) air
filters, located behind the slotted front
(evaporator) air intake door and beneath the left
side (condenser) panel. The evaporator filter can
easily be removed and cleaned; just pull the
front slotted panel down and remove the filter.
The condenser filters are removed by lifting the
filters up and pulling toward you and down.
ELECTRICAL COMPONENT LOCATION
Electrical interconnection is achieved via cables/
wires terminated in an elecrical box located in
the lower back section of the unit. The electrical
box encases the compressor’s run capacitor, a
transformer, the compressor contactor, a freeze
control, a condenser fan speed selector and two
terminal strips.
The manual reset high pressure switch and the
condensate holding tank’s water level detection
system are mounted on opposite sides of the
bulkhead.
1
2
3
4
5
6
7
1. Discharge Grille
2. Control Panel
3. Thermostat Sensing Bulb
4. Evaporator Coil
5. Evaporator Filter
6. Hinged Evaporator
Intake Door
7. Condenser Filter
SERVICE CORD WITH NEMA 6-20 PLUG
PLUG END TERMINATION
JACKET
RECEPTACLE
20A - 230V
NEMA 6-20R
1. Freeze Control
2. Low Voltage
Terminal Block
3. Compressor Capacitor
4. Condenser Fan
Speed Control
5. Contactor
6. Transformer
Electrical Box Closeup
Electrical
Box
2
4
3
1
5
6
SERVICE CORD