Koldfront PAC701W Owner'S Manual Download Page 1

 

 
 
 
 
 
 
 

 

Portable Air Conditioner 

Owner’s Manual 

For more information on other great EdgeStar products on the web, go to http://www.edgestar.com 

PAC701W

 

Summary of Contents for PAC701W

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com PAC701W...

Page 2: ...designed for indoor use only Do not use the unit in extremely humid or wet environments Do not spray water and wet the housing or control panel Do not pull the unit by the cord Always turn the unit of...

Page 3: ...NOTES ABOUT THE EXHAUST HOSE 8 CONTROL PANEL OVERVIEW 9 USING THE CONTROL PANEL 10 LCD DISPLAY 10 MODE INDICATOR LIGHT 10 POWER BUTTON 10 AUTO RESTART 10 WATER FULL LIGHT 10 REMOTE CONTROL SENSOR 10...

Page 4: ...n the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your...

Page 5: ...cation Front View Back View Parts Key 1 Control Panel 2 Air Vent 3 Handle 4 Pre Filter 5 Air Intake 6 Water Outlet Drain 7 Castors 4 8 Continuous Drain Water Outlet for dehumidify mode only 9 Air Outl...

Page 6: ...nts listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as shown in the followin...

Page 7: ...ng the grated adapter 1 Insert the round grated adapter through the back grooved side of the window kit plate with hole 2 Secure the grated adapter by fastening the screws from flat side of the window...

Page 8: ...ide the window kit plate to fit the width of the window You can use screws to secure the window kit plate from sliding 4 Lower the window to secure the window kit in place You may need to use duct tap...

Page 9: ...s to the exhaust hose A B 5 Attach the connectors to the hose A Extend the ends of the exhaust hose B Thread the duct connector on by turning it clockwise until it stops 20 6 Roll the unit towards the...

Page 10: ...tioner and start using it Connecting the duct connector to the unit Connecting the duct connector to the grated adapter 7 Align the slots on the duct connector to the tabs and snap into the back of th...

Page 11: ...en the hose by adding additional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommen...

Page 12: ...anges color to indicate if unit is in Cool mode Blue Light Dehumidify Amber Light or Fan Only mode Green Light Power Button Powers the unit on or off Water Indicator Light The water light will turn on...

Page 13: ...t The unit is in cooling mode Amber light The unit is in dehumidifying mode Green light The unit is in fan mode Use the Power button to turn the portable air conditioner on and off By default when you...

Page 14: ...Function Power Powers the unit on or off Fan Speed Sets the fan speed between high medium or low Timer Used to enable the timer Mode Changes between cool dehumidify and fan modes Up Increases the set...

Page 15: ...Indicator Light on the Control Panel turns blue 4 Select the fan speed by using the Speed button 5 Set the thermostat by using the Up and Down buttons The thermostat is adjustable between 61 F 89 F in...

Page 16: ...ol while the unit is powered off 2 Use the Up and Down buttons on the remote to set the time displayed in hours you want to pass before the unit turns on After the selected time passes the unit will a...

Page 17: ...running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly before reinstalling Clean the pre filter period...

Page 18: ...he timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources d...

Page 19: ...mer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fan Remove the object from the fan The floor below...

Page 20: ...t to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The...

Page 21: ...iption of product Portable Air Conditioner Model PAC701W Voltage Frequency AC 115V 60Hz Input Power 650W Current 6 0A Color White Dehumidifying capacity 61 Pints Day Coolant R 410A Timer 24 Hour Dimen...

Page 22: ...nstruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s ma...

Page 23: ...m E mail service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar Koldfront products on the w...

Reviews: