9.The installation for the crusher and ice machine(s) should be complete. Place the panels back
onto the ice machine. If the crusher is needed for a crush only operation, do not put the crusher
panels back on yet.
OPERATION OF T281-T284 CRUSHER
1.
The crusher operates by using the switch located behind the front panel and selecting
what side of the bin you want to fill first.
2.
If Crush is selected the crush will move the flapper to allow crushed ice into the crush
side of the bin until that side is full determined by the bin probe.
3.
If Cube is selected then the flapper moves to allow cubed ice fall into the right side of
the bin until that becomes full.
4.
Once any side is full the flapper will automatically move to the opposite side and will
remain there until that side becomes full. The operation will automatically continue
like this until both sides are full.
5.
If both sides become full the ice machine(s) will shut down and remain like this until
one side calls for ice at which point the machine will turn back on and fill said side.
SETTING T281-T284 to a CRUSH ONLY OPERATION
1.
In order to create a crush only operation for the crusher you must remove the cube
side probe located at the crusher control box.
NOTE: Before removing or replacing the probe disconnect power to the crusher.
2.
The cube side probe is located on the control box and is labeled EVAP (Left Side).
The location is shown in
Figure 10
.
Figure 10
3.
After removing the cube probe from its port the panels can be placed back on and
power connected. The position of the switch will not matter once the probe is
removed. This will create a crush only operation and continue until the crush side is
Cube Probe
Summary of Contents for AKD-125
Page 9: ...9 equipment damage GT GB SCHEMATICS GT360 AIR LIQUID WIRING DIAGRAM ...
Page 10: ...10 GB GB560 AIR LIQUID WIRING DIAGRAM ...
Page 11: ...11 GT GB560 REMOTE WIRING DIAGRAM ...
Page 12: ...12 GB1064 AIR LIQUID WIRING DIAGRAM ...
Page 13: ...13 GB1064 REMOTE WIRING DIAGRAM ...
Page 21: ...21 6 Install gasket on top of dispenser See Illustration A ...