8. Warranty claims and liability for
defects
8.1 We provide a 24 month warranty on our products
according to German law. Prerequisites for this are
single-shift operations and completion of a machine
service check after 12 months, as calculated from the
date of delivery from the factory, performed by KOLBE
or an authorized service technician.
8.2 The warranty provides for the repair or replacement
through our facilities or specifically authorised repair
workshops, of all products shown to be defective during
the period of the warranty due to verifiable material or
manufacturing defects.
8.3 Excluded from any liability for defects are all parts subject
to natural wear and tear, as well as the consequences
resulting from excessive loading, improper cleaning,
faulty handling and non-compliance with the Operating
Manual.
8.4 We assume absolutely no responsibility for arbitrary
tampering of the object of any kind by the customer or
a third party without our specific order to do so.
8.5 Products manufactured by us are subject to the
provisions of the EC Machinery Directive.
Cleaning instructions
For KOLBE mixer mincer machines
Machine zones requiring special and careful cleaning:
Cleaning zones
Cleaning agent
Procedure
Device
Instructions
Removable parts:
• Mincer feed screw, cutting set,
removable mincer housing, feed
screw, mixing blade, locking nut,
loosening device, etc.
• Mincer housing attachment bolts
according to the
Cleaning plan
manually,
mechanically
Scrub brush,
Brush
Disassemble parts and clean
in a tub or dishwasher, thor-
oughly clean out threads with
a scrub brush or brush.
Mincer stand and mincer hopper:
• Housing outlet protective cover
(if available)
• Mincer housing attachment and
transfer housing
• Outer and inner areas of the
mincer bowl or filling hopper
• Mincer base frame and retractable
trays (if available)
• Rear, side inspection access covers
according to the
Cleaning plan
manually,
mechanically
Scrub brush,
Brush
Thoroughly clean outer and in-
ner areas with a scrub brush
or brush. Thoroughly clean the
base frame with a scrub brush
or brush. Thoroughly clean
outer contours and inspection
covers with a scrub brush or
brush.