7.2
Remplacer le fusible du compteur horaire
The fuse for the working hours counter (A18) must be changed if there is a fault with the working hours counter (A11).
1.
Before replacing the worn fuse with a new one, always identify the cause of the fault (consult one of our agents).
2.
Disconnect the battery (A2).
3.
Unscrew the fuse holder and check the condition of the fuse.
4.
Replace the blown fuse with a fuse with the same technical specifications.
Using an incorrect fuse may result in damage to the unit.
5.
Unscrew the fuse holder.
6.
Reconnect the battery.
7.3
Generator Smart Care
If the unit has been equipped with the "GS101-Generator Smart Care" option (A19),
it is necessary to change the batteries in the Bluetooth GSC101 box when the
warning is displayed in the Generator Smart Care application (approximately every
two years).
1.
Use a small crosshead screwdriver to open the cover of the box,
2.
Remove the used batteries and take them to a waste collection point so
that they can be recycled,
3.
Fit two new AAA batteries, observing the polarity (+/-),
4.
Close the unit cover and carefully tighten the screws.
Section 8. Technical specifications
8.1
Operating conditions
The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
8.2
Capacity of the generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*
This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher
load when starting. This minimum required power must not exceed the unit's maximum power
.
8.3
Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
power level
(D):
Maximum power
(E):
Nominal power
(F):
Power factor
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Electrical voltage
(K):
Protection rating
(L):
Reference standard
(M): Serial number
(N):
UKCA marking
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
Engine brand:
(e.g. Kohler)
Engine serial number:
(e.g. Kohler (SERIAL NO. 4001200908))
……/………….. - ……..………..….…. - ………
……..……..………..….…..….
……..………..….….……..………..….….
(D)
(E)
(A)
(B)
(N)
(F)
(I)
(H)
(J)
(K)
(L)
(M)
(G)
(c)
23/226
Summary of Contents for SDMO TECHNIC 6500 E C5
Page 2: ...A 18 7 11 1 3 15 9 6 2 5 4 10 17 12 6 13 14 16 8 19...
Page 3: ...B C 2 3 5 1 4 8 7 6 3 4 1 2 5 H...
Page 4: ...D E F FRANCE 0 806 800 107 Prix appel 5 1 2 6 3 4 1 3 2 2 1...
Page 18: ...1132_FR 2021 07 06 14 226...
Page 46: ...1132_ES docx 2021 07 06 42 226...
Page 60: ...1132_DE docx 2021 07 06 56 226...
Page 74: ...1132_NL docx 2021 07 06 70 226...
Page 88: ...1132_DA docx 2021 07 06 84 226...
Page 113: ...1132_RU docx 2021 07 06 C 1 2 3 4 5 6 7 8 9 1 2 2 1 1 2 3 1 2 3 2 2 2 3 109 226...
Page 188: ...1132_RO docx 2021 07 06 184 226...
Page 189: ...1132_BG docx 2021 07 06 1 2 3 4 5 6 7 8 9 1 2 2 1 1 2 3 1 2 3 2 2 2 3 185 226...
Page 203: ...1132_EL docx 2021 07 06 1 2 3 4 5 6 7 8 9 1 Internet 2 2 1 1 2 3 1 2 3 2 2 199 226...
Page 204: ...1132_EL docx 2021 07 06 2 3 2 4 2 5 30 2 6 30 2 7 2 7 1 A 30 mA 1 B TN TT 10 mm2 A1 1 200 226...
Page 217: ...1132_AR 2021 07 06 1 2 3 4 5 6 7 8 9 1 2 2 1 1 2 3 1 2 3 2 2 2 3 2 4 213 226...
Page 230: ...1132_AR 2021 07 06 226 226...