BEFORE YOU BEGIN     

BEFORE YOU BEGIN     

TOUCHLESS URINAL SENSOR

 

72870T-ST  

TOUCHLESS URINAL SENSOR

 

72870T-ST  

Please read these instructions carefully to familiarize

    yourself with the required tools, materials, and installation
    sequences. Follow the sections that pertain to your
    particular installation. This will help you avoid costly
    mistakes. In addition to proper installation, read all
    operating and safety instructions.

All information in these instructions is based upon the

    latest product information available at the time of
    publication. Kohler China reserves the right to make
    changes in product characteristics, packaging, or
    availability at any time without notice.

These instructions contain important care, cleaning, and

    warranty information -
    please leave instructions for the consumer

  
  
  

  
  

  -

RECOMMENDED TOOLS AND MATERIALS 

RECOMMENDED TOOLS AND MATERIALS 

 Open end/adjustable wrenches

 Tape measure

 Basin wrench

 Pipe wrench

 Square

 Level

 Pliers

 Socket wrench with sockets

 Philips driver

 Seal tape

 Special wrenches

 Wire cutter

 Insulation tape

 Bushing

 /
 
 
 
 
 
 
 
 
 
 
 
 
 

SENSOR SPECIFICATIONS 

SENSOR SPECIFICATIONS 

 

    

72870T-ST 

 

    

AC 220V

DC 6V

4

AA

             

             

 

    

 

0.3mW 

 

3W 

 150,000

 10-70cm(

)

 1-60

 0.07Mpa 

-0.7Mpa

 G1/2

  

 

2

 

2

 

6

   

0.3Mpa

3-5L

 95RH

 Model

72870T-ST 

Power

AC 220V/DC 6V (4pcs AA alkaline batteries)

                  Can use dual power supply switches autom

                  atically, or used alone AC or DC.

 Power consumption: static state 0.3mW trends 3W 

 Battery life

150,000 cycles

 Sensing range

10-70cm( adjustable)

 Working temperature

1-60

 Working pressure

0.07Mpa -0.7Mpa

 Water interface

G1/2

external thread

 Installation: concealed into the wall

 Flushing way

two-stage flush, the first is 2 seconds, 

     the second is 6 seconds

 Rated flow: flush water about 3-5L when the water 

     pressure is 0.3Mpa 

 Environment humidity: below 95RH

 

Summary of Contents for KARAT 72870T-ST

Page 1: ... the consumer RECOMMENDED TOOLS AND MATERIALS RECOMMENDED TOOLS AND MATERIALS Open end adjustable wrenches Tape measure Basin wrench Pipe wrench Square Level Pliers Socket wrench with sockets Philips driver Seal tape Special wrenches Wire cutter Insulation tape Bushing SENSOR SPECIFICATIONS SENSOR SPECIFICATIONS 72870T ST AC 220V DC 6V 4 AA 0 3mW 3W 150 000 10 70cm 1 60 0 07Mpa 0 7Mpa G1 2 2 2 6 0...

Page 2: ...e the installation location per rough in dimensions and the table of installation position Chisel out a slot and install the supply tubes Then flush the supply tubes The depth of the slot is not less than 90mm see the figure to the right for rough in dimension requirement See the figure right for rough in dimension requirement Notice a No light shall enter or be reflected into the sensing window b...

Page 3: ...r with the 2 AC 220V power wires then use electrical tape to wrapped separately c Open the battery holder put into 4 pieces AA alkaline batteries d Put the power adapter and battery holder into the mortar see Figure 4 3 Connected to water with a boosting device for pipeline pressure to 0 7Mpa and check the connectors have no leaks 4 Remounted the protective cover with mortar to landfill cracks aro...

Page 4: ... sensing range up to 2 seconds flushing about 2 seconds and flushing about 6 seconds after left At the time of induction indicate when the indicator flash once every 3 seconds for more than three minutes of the induction time the indicator light will blink rapidly To adjust the water flow with a sucker to take down the panel with straight screwdriver to adjust the flow clockwise and counter clockw...

Page 5: ... soft cloth and mild cleaner a b a b c d 2007 Our company has an extensive quality promise to the end customers The karat products proven to be correctly installed and properly used enjoy a mainten ance period of 1 year during which any products with quality defects shall be repaired without any charge Quality defects caused by the following factors are not included in the promise 1 Quality defect...

Page 6: ...tteries Check the power or change new batteries 3 Wrong with control box module should change it 3 No water The in person front of the sensor window the indicator flash 1 time it means as follow 1 Bad connection of solenoid valve line or fault with it please change solenoid valve module 2 The filter was blocked in water inlet of solenoid valve please clean the filter 4 No water The indicator flash...

Page 7: ...or acid alkali water and impure water 8 When AC power unit is connected to 220V AC power supply corresponding protective measures should be taken 9 Please confirm no water penetration at the connection area of AC wire and the connection area is not easy to be affected by damp 10 Don t connect power unit to AC power supply until the sensor installation is finished 11 The head AC power supply must b...

Page 8: ...OM Valve Body POM 220V 1244999 Solenoid Valve Screw 1245000 Valve Box 1245006 Sucke 1245023 Bracket Assy 1245001 Slurry Mold 1245002 Control Box Assy 1245004 Panel Screw 1245003 Panel 1245005 AC DC Transformer 1244990 Battery Box Assy SERVICEPARTSPAGE SERVICEPARTSPAGE TOUCHLESS URINAL SENSOR 72870T ST TOUCHLESS URINAL SENSOR 72870T ST ...