Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -

.

please leave instructions for the

consumer

·

·

·

-

·

·

·

·

·

·

·

·

·

·

·

·

·

·

Open end/adjustable wrenches
Tape measure
Basin wrench
Pipe wrench
Square
Level
Pliers
Socket wrench with sockets
Screw driver
Seal tape
Connection wire
Wire cutter
Insulation tape
Bushing

·

·

·

·

·

·

·

·

·

·

·

·

·

·

/

RECOMMENDED TOOLS AND MATERIALS

RECOMMENDED TOOLS AND MATERIALS

SENSOR SPECIFICATION

SENSOR SPECIFICATION

Model

8787T-C03(AC)

8787T-C01(DC)

Power

4 AA size alkaline batteries
(8787T-C01)

"

"

220V AC 50/60Hz(8787T-C03)

Liter per flushing

Water pressure 0.3 MPa: about 2~4L
(Automatic adjustment)
Water pressure 0.1MPa no more than 3L

Temperature

Environmental temperature: 1 to 60

Starting pressure

0.05~0.7MPa

Sensing distance

80cm away from sensing window
(adjustable)

Testing time

About 2 seconds (or set to 5 seconds)

30

30cm

2

Note:

The sensing distance in the table is measured with a

30

30cm white board as the reflecting surface.

2

8787T-C03(

)

8787T-C01(

)

4

5

(AA

4)

(8787T-C01)

220V AC 50/60Hz(8787T-C03)

0.3 MPa

2~4L

(

)

0.1MPa

3L

: 1

~60

0.05~0.7MPa

80cm

(

)

2

(

5

)

BARDON

TOUCHLESS URINAL SENSOR (WATER SAVING)

INSTALLATION INSTRUCTIONS

K-8787T-C01(DC/

)

K-8787T-C03(AC/

)

-1-

, 2007

Copyright Kohler China Ltd., 2007

18

E

201206

1020018-T01-C

Summary of Contents for Bardon K-8787T-C01

Page 1: ...h sockets Screw driver Seal tape Connection wire Wire cutter Insulation tape Bushing RECOMMENDED TOOLS AND MATERIALS RECOMMENDED TOOLS AND MATERIALS SENSOR SPECIFICATION SENSOR SPECIFICATION Model 8787T C03 AC 8787T C01 DC Power 4 AA size alkaline batteries 8787T C01 220V AC 50 60Hz 8787T C03 Liter per flushing Water pressure 0 3 MPa about 2 4L Automatic adjustment Water pressure 0 1MPa no more th...

Page 2: ...ug In 1020021 Rubber Plugs 1020011 Angles Long Screws 4 pcs M4 50 4 M4 50 Cover Screw 2 M3 6 pcs 2 M3 6 1020029 Flushing Valve Assy 1020979 Solenoid Valve Assy 1019266 Sensor Lens Seal Washer Control Box Battery Cover 1019270 Control Box Assy 1021642 Fixed Cap 1020028 O O Big Ring 1021472 Filter Connection Ring O O Outlet Connection 1021431 Pertain 2 Small Ring O O Nut AC 16305T NA 8787T C03 Use o...

Page 3: ... 1 2 R1 2 3 INSTALLATION 1 Notice Determine the installation location per rough in dimensions Chisel out a slot and install the supply tubing Turn off the water supply The depth of the slot is no less than 105mm see the figure right for rough in dimension requirement installation location a No light shall enter or be reflected into the sensing window b No reflectible objects in front of the sensin...

Page 4: ...e match 16305T NA AC power unit when installing 8787T C03 AC The way of installation is as below a Outlet of AC power unit upward prohibited b Do not connect 220V AC power supply to DC wiring terminal c Do not damage the covering of AC power unit or remove screws to avoid leakage CAUTION Outlet downwards Outlet upwards Connect to sensor Connect to AC Power supply A 1 2 Connect to AC Power supply 8...

Page 5: ... outlet Don t lose the connection O rings c Do not connect the DC output of AC power unit to AC power supply d Do not connect to power supply while installing Connection line is not supplied AC connection wire with insulating sleeving is recommended Wire of which the nominal section area of conductor is not less than 0 5mm is also recommended DC connection line use wire of which the nominal sectio...

Page 6: ... long screws 4 5 a Buckle the sensor cover into the wall slightly above bracket assy b Press the sensor cover down along the wall and fit tightly into the bracket assy c Push upward with basin wrench and rotate clockwise to lock the sensor cover While using DC power for 8787T C01 remove the battery cover and put in 4 AA size alkaline batteries and tighten the screws C While using AC power for 8787...

Page 7: ... GUIDE USER S GUIDE Don t use this system until the power is on for 10 minutes The sensing distance will be adjusted and the system will not work during the time Users can set the working status as needed per the table below by turning on the right switch The four status options S 1 S 3 and S 4 have been set ON statuses and S 2 has been set OFF status in the factory After setting plug the rubber p...

Page 8: ...thin 10 minutes shut off the power Wait for the indicator to stop flashing Turn on the power supply and repeat the procedure The sensing distance is set to its max value in factory The angle of ultra red radiation is 15 degrees down It s adjustable when the bathroom is narrow and crowded When adjusting remove the panel and the rubber plug and adjust the potentiometer Make sure to insert the rubber...

Page 9: ...e adjusting bolt before cleaning Notice Care Clean Keep the sensing window clean Wipe with soft cloth and mild cleaner a Do not use dust removing powder abrasive powder or cleaner containing oil acid or alkaline ingredient b Do not spray air refresher disinfector or other deodorizing cleaning solvent directly into the sensing window c Keep wire away from water d Don t attack the sensor window Noti...

Page 10: ...in valve unit Out of electricity Only for 8787T C01 1 2 Remove the object or reduce the sensing distance 3 Clean the window Check the power connect 1 Wait for 10 minutes 2 Open the adjusting bolt 3 Improve water supply 4 Clean the filter 5 Terminate manual status or wait for the status to end Repeat the sensing action several times after cleaning the filter Replace batteries Only for 8787T C01 Ple...

Page 11: ...aning organic liquid to the sensor directly 7 Urinal is designed for use with potable water Avoid water that includes a lot of contaminants or acid alkali water and impure water 8 When AC power unit is connected to 220V AC power supply corresponding protective measures should be taken 9 Please confirm no water penetration at the connection area of AC wire and the connection area is not easy to be ...

Reviews: