DRV300 User Guide

Connections

Terminal block

VCC

: Supply input. Connect this pin to a 9V supply.

EN

: Laser Enable pin. Apply a voltage between 2.2 V and 4.5 V to enable the laser current.

TRIM

: Laser current trimming input with 2 kΩ input impedance, ± 2 V input voltage range and 10 Hz

bandwidth. Gain is 10 mA/V for the 200 mA version.

IMON

: Laser current monitoring pin. The voltage at this pin is proportional to the laser current (5 V/A for

the 200 mA version).

LD+

: Laser anode pin. Connect this pin to the laser anode.

GND

: Ground. Connect this pin to the laser cathode.

Switch

EN

: Enable / disable laser current.

ILIM

: Set to ON/OFF for Low/High current limit.

G0 / G1

: Set modulation gain as follows:

1 / 2