DRV300 User Guide
Connections
Terminal block
VCC
: Supply input. Connect this pin to a 9V supply.
EN
: Laser Enable pin. Apply a voltage between 2.2 V and 4.5 V to enable the laser current.
TRIM
: Laser current trimming input with 2 kΩ input impedance, ± 2 V input voltage range and 10 Hz
bandwidth. Gain is 10 mA/V for the 200 mA version.
IMON
: Laser current monitoring pin. The voltage at this pin is proportional to the laser current (5 V/A for
the 200 mA version).
LD+
: Laser anode pin. Connect this pin to the laser anode.
GND
: Ground. Connect this pin to the laser cathode.
Switch
EN
: Enable / disable laser current.
ILIM
: Set to ON/OFF for Low/High current limit.
G0 / G1
: Set modulation gain as follows:
1 / 2
DRV300
www.koheron.com