Koheron CTL100 User Manual Download Page 1

Laser connections 
The CTL100 is compatible with Type 2 butterfly laser diodes. Note that is is only 
compatible with floating diodes, which means that neither the anode nor the cathode 
should be connected to the case. 

Enable switch 
1 ON: Enable laser current. 
2 ON: Enable TEC current. Turn off the power supply before changing this switch. 

Terminal block connections 
•VCC: Connect this pin to a 5V power supply (2 A minimum). The high power supply 
rejection of the current driver allows the use of a switched power supply with minor 
degradation of the noise performance. At a laser current of 400 mA, the CTL100 draws 510 
mA (TEC current disabled). An eFUSE protects the CTL100 against overvoltage (6.1 V) and 
overcurrent (2 A). 

 

•TACT: Temperature monitoring pin. The thermistor value is given by R

th

 = 10 

k

Ω

×(10.5V−V

TACT

)/(5.5V+V

TACT

). The output is current-limited with a 1 k

Ω

 resistor. 

•TSET: Temperature setpoint monitoring pin. V

TSET

=V

TREF

+V

TMOD

/10, where V

TREF

 is the voltage 

generated by the temperature trimming potentiometer. The voltage V

TREF

 can be tuned 

between 0 and 2.5 V and can be measured at test point TP2. V

TMOD

 is the voltage applied at 

the TMOD pin. The PID controller tries to make the voltage V

TACT

 equal to the setpoint V

TSET

The output current is limited with a 1 k

Ω

 resistor. 

Reviews: