Chapter 3 Installation
MDS-1100R Series
3-4
0092642260-01
Specification of bracket thickness-wise installation bolt (In case of RB805)
Thickness of bracket
Bolt for fixing the antenna
Material
Remarks
4 to 9 mm (0.16 to 0.35 in)
M10x20 (pitch 1.5mm)
stainless
9 to 14mm (0.35 to 0.55 in)
M10x25 (pitch 1.5mm)
stainless
Included in accessories
14 to 19 mm (0.55 to 0.75in)
M10x30 (pitch 1.5mm)
stainless
3.3.2 Setting of Open Antenna
As illustrated below, install the drive block, facing the cut portion of the installation base toward the
stern. This makes it easier to perform the maintenance
1.
Referring to the illustration below, make holes of 14mm diameter on the installation side of
platform.
2.
Place the Scanner unit at the specified position and fix it with four 12mm stainless bolts included in
the installation material. If the thickness of the bracket is 9 to 14mm, the bracket can be installed
with the supplied bolts. If not within this range, prepare the bolts shown on the table in the next
page.
Unit: mm (inch)
100 φ
Plain view of mounting hole
199
(7.83)
185
(7.28)
(0.55)
(3.97)
Notch of Scanner
Heading
Antenna rotating radius
R600 (3 ft Antenna unit)
R700 (4 ft Antenna unit)
R1000 (6 ft Antenna unit)
R1400 (9 ft Antenna unit)
14
φx 4
Cable opening
Summary of Contents for MDS-1100R Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 8: ... This page intentionally left blank ...
Page 12: ... This page intentionally left blank ...
Page 16: ... This page intentionally left blank ...
Page 24: ... This page intentionally left blank ...
Page 62: ... This page intentionally left blank ...
Page 67: ...MDS 1100R Series Chapter 5 Maintenance 0092642260 01 5 5 RB806 RB807 717A Unit mm inch ...
Page 68: ...Chapter 5 Maintenance MDS 1100R Series 5 6 0092642260 01 RB808 718A RB809 719A Unit mm inch ...
Page 69: ...MDS 1100R Series Chapter 5 Maintenance 0092642260 01 5 7 MDS 11R Unit mm inch ...
Page 70: ......