Chapter 9 Simple fault diagnosis
MDC-7000/7900 Series
0093169010-10
9-2
9.1
No alarm sound
Follow this procedure to troubleshoot no alarm sound trouble.
First, select [SYSTEM] => [SOUND] => [SOUND] and confirm that the status is [ON].
1
Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [BITE] => [ALARM TEST] => [ON], and press ENT key after selection.
2
Please confirm the frequency setting, because it may be hard to hear the alarm sound
according to the setting value.
Select
[SYSTEM] => [SOUND] => [FREQUENCY] (Initial setting: 4)
3
Alarm sounds (two times) and alarm display appears at the lower right of the display.
Alarms displayed are [WARNING B 999], [Test alert only.]
.
4
Confirmation is completed if alarm sounded.
5
Alarm sounds are repeated every 60 seconds.
Select [MAINTENANCE] => [BITE] => [ALARM TEST] => [OFF], and press ENT key to turn alarm
test off.
Note: After running the test and there is still no alarm sound the Operation unit has malfunction.
Summary of Contents for MDC-7010
Page 1: ......
Page 2: ......
Page 144: ... This page intentionally left blank ...
Page 170: ... This page intentionally left blank ...
Page 176: ... This page intentionally left blank ...
Page 192: ... This page intentionally left blank ...
Page 234: ......