![Koden MDC-5204 Installation Manual Download Page 35](http://html.mh-extra.com/html/koden/mdc-5204/mdc-5204_installation-manual_1984780035.webp)
MDC-5200/5500 Series
Chapter 3 Installation method
0092655002-03
3-11
23) Attach the back cover by tightening four fixing
bolts.
(Tool: Wrench 13mm)
20) Remove the screw-A and the screw-B.
B
Clamping band
A
Connecting cable
Shield braid terminal
Clamping band
21) Clamp the connecting cable by the
clamping band and fix with screw-A.
Fix the shield braid terminal with screw-B.
22) Connect connector P2 to J2 [PCB E61-120x].
Connect the connectors P1 and P3 to J1 and J3
[PCB E71-110X].
P3 -> J3
P2 -> J2
PCB: E61-120X
PCB: E71-110X
P1 -> J1