![Koden MDC-5204 Installation Manual Download Page 30](http://html.mh-extra.com/html/koden/mdc-5204/mdc-5204_installation-manual_1984780030.webp)
Chapter 3 Installation method
MDC-5200/5500 Series
3-6
0092655002-03
3.1.4 Installation of the connecting cable CW-845-xxM
3.1.4.1 Scanner unit 6kW (RB807: MDC-5206/5506)
Make sure the radar system is turned off.
1) Remove back cover by loosening four fixing
bolts.
(Tool: Wrench 13mm)
2) Disconnect connectors P3 from J3
[E61-120X].
Remove the two fixing bolts.
(Tool: Wrench 13mm)
PCB: E61-120X
P3 <- J3
Bolt
Bolt
3) Pull out the TR unit, remove the
cable clamp.
TR unit
Cable clamp
4) Disconnect connector P2 from J2 and
P2 from J5.
P2 <- J2
PCB: E71-110X
P2 <- J5