5.3.2 Malfunction diagnostics flow chart
The following malfunction analysis chart can be used by service personnel for malfunction diagnostics
and location of defective module. This chart shows flow chart of dignostics for basic malfunction
troubleshooting.
5.3.2.1 Initial malfunction diagnostics
Can operation unit operate?
Is the model name seen during
preheating countdown time?
Power
“ON” the Radar.
Yes
Start transmitting
Are radar echos normal?
Does short buzzer sound?
Are radar echos displayed?
No
Go to [5.3.2.8 Data such as heading, speed,
latitude/longitude cannot be received].
Go to [5.3.2.5 Operation unit error].
Go to [5.3.2.6 No radar echo].
Go to [5.3.2.4 No response from the
antenna unit].
Go to [5.3.2.3 No display].
No
No
Yes
No
Yes
Yes
Yes
Yes
Other errors
Are any message displayed?
Is the NMEA serial input data
displayed?
Is the AIS data displayed?
Yes
No
Go to [5.3.2.7 Weak sensitivity of the radar
echo].
No
No
No
Go to [5.3.2.9 AIS].
Go to [5.3.2.2 Cannot turn on the power].
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......