capacitor is discharged in a suitable manner when checking the inside of the antenna. Maintenance
and inspection should be conducted by qualified engineers only.
Precautions for maintenance
• Caution against residual high voltage:
Capacitors used in the Processor unit and the modulator circuit of the transmission unit may keep high
voltage for several minutes even after turning off power. The maintenance and inspection of this part
should be performed at least 5 minutes after powering off or applying the appropriate measure to
discharge the residual electrical charge.
• Keep inboard power source “Off”:
An electric shock is possible if the power switch is accidentally turned on during the maintenance
operation. In order to prevent such an occurrence, please ensure to disconnect the power breaker of
the onboard power source and the device. Furthermore, it is recommended to post the word-of-caution
tag shown to be in a "working state" near the power switch of the device.
• Caution against the dust:
Dust can temporarily cause distress to the respiratory system. Take care not to inhale dust when
cleaning the interior of the device. It is recommended you wear a safety mask.
• Measures against static electricity:
Static electricity occurring from carpet on the floor of the cabin, clothes made of synthetic fiber etc., may
damage some electronic parts on the printed circuit board. Please work on the printed circuit board only
after taking measures against static electricity.
• Prohibited matter:
Any Processor unit and Scanner unit combination other than specified in the manual is prohibited and
will void manufacturer’s warranty.
• Break in procedure of stored radar:
Following procedure is recommended for “Break In” of the stored radar.
Otherwise the radar sometimes exhibits unstable transmitting operation such as arcing at its initial
operation after long period of storage and make the operation more difficult.
1. Extend preheat time as long as possible (preferably 20 to 30 minutes).
2. Set the pulse width to the shortest one and start the operation.
When the operation in the shortest pulse is stable then go to operation in longer pulse and repeat
the similar step until the operation reaches to the final pulse condition.
Summary of Contents for MDC-5004
Page 1: ......
Page 2: ......
Page 20: ...Chapter 3 installation method MDC 5000 Series 3 2 0092653004 00 RB808 RB809 Unit mm inch ...
Page 88: ... This page intentionally left blank ...
Page 114: ... This page intentionally left blank ...
Page 130: ... This page intentionally left blank ...
Page 150: ... This page intentionally left blank ...
Page 151: ...0092653004 00 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 152: ...A 2 0092653004 00 INTER CONNECTION DIAGRAM RB807 ...
Page 153: ...0092653004 00 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 154: ...A 4 0092653004 00 INTER CONNECTION DIAGRAM RB809 ...
Page 155: ...0092653004 00 A 5 INTER CONNECTION DIAGRAM MRM 110 MRO 110 ...
Page 156: ......