4.6 Display Installation
The display unit is designed for table mount and flush mount. Refer to the following descriptions for
installation.
4.6.1 Table mounting
(1) Remove the two fixing knobs that fix the display unit to the mounting bracket.
(2) Remove the display unit from the bracket and place it on a flat and safe area.
(3) Place the mounting bracket to the place where the display unit is to be installed, and fix the bracket
with four (4) tapping screws.
(4) Reset the display unit on to the bracket and fix it using the two screws that were removed in step (1).
Refer to the following figures for detail.
GTD-110/150
The EMI noise is terminated with battery’s internal impedance, preventing the noise
from entering the GTD-110/150 display unit.
EMI noise from other equipment
+
+
[Good wiring]
Battery
The line length between a battery and connecting points of power cable produces
higher impedance than that of the battery, causing the EMI noise to be induced in the
GTD-110/150 display unit.
Figure 4.1 Recommended power supply line connections
KS-2001
+
+
[Inappropriate wiring]
Battery
EMI noise from other equipment