ERROR CODE

CAUSE

SOLUTION

e001

all battery over-voltage protection.

no charge, only discharge.

e002

all battery low-voltage protection.

fully charged and restart.

e003

all battery failure.

restart kodak ppS1800 and charge it.

e004

all battery discharge 

over-temperature protection.

temperature is too high. 

restart when cooler.

e005

all battery discharge 

low-temperature protection.

ambient environment temperature is too low. 

restart when environment temperature is higher.

e006

all battery charge 

over-temperature protection.

the temperature of the battery pack is too high. 

charge when the temperature is lower.

e007

all battery charge

low-temperature protection.

the temperature of the battery pack is too low. 

charge when the temperature is higher.

e008

1st group battery 

low-voltage protection.

charge and restart.

e009

2nd group battery 

low-voltage protection.

charge and restart.

e010

3rd group battery 

low-voltage protection.

charge and restart.

e011

4th group battery 

low-voltage protection.

charge and restart.

e012

inverter bus cable voltage failure.

turn off and restart.

e013

inverter over-load protection.

reduce the load. restart ac.

e014

inverter short-circuit.

correct the short-circuit output. restart ac.

e015

inverter cooling fan discharge 

over-temperature protection.

restart when the cooling fan temperature is 

lower.

e016

inverter cooling fan temperature 

detector is not working.

connect ntc and restart.

e017

pV input over-voltage protection.

check to ensure you have correctly configured 

the solar panel array to provide the correct 

input voltage. 

if yes: disconnect pV and turn back on and 

connect pV

e018

internal over-temperature protection. check if the working temperature is too high.  

if the temperature is within the operating 

range, disconnect the pV, switch off the device 

and then reconnect the pV.

e019

pV cooling fan over-temperature 

protection.

recharge after the cooling fan temperature is 

lower.

e020

pV cooling fan temperature 

detector is not working.

restart kodak ppS1800.

e021

battery protection board charge 

protection.

recharge after the protection board tempera-

ture is back to normal

e022

battery false protection.

disconnect pV. restart.

e023

Generator over-load (ac&dc) 

protection.

reduce the total load and restart.

9. TROUBLESHOOTING

Summary of Contents for PPS1800

Page 1: ...KODAK Portable Power Station ppS1800 user manual please read this manual carefully before operating the product please keep this manual with you for further reference ...

Page 2: ...ing 11 6 1 PV SOLAR PANEL CHARGE ACTIVATION 11 6 2 DiSPLAY 11 7 Technical specifications 12 8 Using the KODAK PPS1800 13 9 Troubleshooting 14 10 Frequently Asked Questions FAQ 15 11 Storage and downtime maintenance 16 12 Service life of lithium ion batteries 16 13 Disposal and recycling 17 14 customer service 18 CONTENTS ...

Page 3: ...3 1 SET INCLUDES No Item Quantity 1 kodak portable power Station ppS1800 1 2 ac charger 1 3 1 5m mc4 to dc7909 cable 1 4 user manual 1 1 4 2 3 Portable Power Station ppS1800 user manual ...

Page 4: ...dents intentional misconduct on the part of the customer abuse or other abnormal conditions Do not repair any damage to the AC plug or power supply on your own The warranty covers all terms and conditions of the warranty Contents that are not specified in the warranty terms and conditions are beyond our responsibility Our company assumes no liability for damages caused by incorrect use or non comp...

Page 5: ...N means Noncompliance may damage the unit Serious injuries include blindness burns electric shock fractures poisoning etc which can lead to complications hospitalization or permanent treatment Injuries include burns electric shock etc which usually do not lead to hospitalization or permanent treatment Property damage includes buildings belongings and pets etc This device complies with part 15 of t...

Page 6: ... in electric shock Do NOT connect any metallic objects to the AC input or output Doing so may result in electric shock fire etc Do NOT rub your eyes if fluid from inside the unit should get in your eyes If this should occur flush eyes with water and seek medical attention immediately This can lead to blindness Do NOT dispose the unit together with household waste Follow the local law to dispose th...

Page 7: ...ay with the unit This unit may only be used by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they are monitored or have been instructed in how to safely use the unit and understand the resulting risks Keep this product away from pets Do NOT use or store the unit in an area or environment with high temperature Doing so may cause the unit to defo...

Page 8: ... charge and use the unit within an ambient temperature of 0 to 40 C 32 104 F Operating the unit above or below this temperature range may result in overheating or reduced perfor mance Switch the unit off immediately if it has accidentally fallen was dropped or was exposed to vibrations To prevent accidents please contact the dealer or our customer service center to have the unit checked and repair...

Page 9: ... is never allowed to fall to the ground 2 Placing the unit on a stable surface ATTENTION Place the unit on a stable surface By doing so it is also easier to read the indicators 3 Transporting the device DANGER The unit should not be subjected to any impact or vibrations Otherwise there is a risk of fire Keep the unit s original packaging and use it when you need to transport the unit ...

Page 10: ...output button C AC output button D LED indicator light E 5V USB output F Type C output G Display Battery status indicator H Charger PV charge input port DC7909 I 12V cigarette lighter port J 230V AC output Type F 5 GET TO KNOW YOUR KODAK PPS1800 A G H I J B C E F D ...

Page 11: ...ctivate these outputs NOTE If the Master power button is not turned on the AC button and DC buttons are in offline status with no AC and DC output If Master power button is turned on the AC and DC buttons are still in offline mode and there will be no AC or DC output You need to turn on the AC and DC power button separately NOTE 1 Failure codes E see 9 Troubleshooting will appear in the position o...

Page 12: ...cy 230 Vac 50Hz Inverter output Pure Sine Wave Power factor 1 Overload 1000W load 1200W 2min 1200W load 1sec Max efficiency 70 load 90 USB Type C Cigarette Lighter output ports USB ports 5V 3A max output is 3A for one USB port max output is 3A for one group of 2 USB ports combined Type C port PD 2 0 5 20V default is 5V 5V 9V 12V 15V 3A 20V 2 25A Fast charge protocol PD 2 0 max 45W Cigarette lighte...

Page 13: ...elligent cooling KODAKs PPS1800 intelligent system will turn on fans for cooling when any of these conditions are met 1 Inverter load 400W 2 5V USB load 10W 3 TypeC PD load 30W 4 12V cigarette lighter load 50W 5 PV input power 100W In addition KODAKs PPS1800 intelligent controll system will adjust the PV input or AC output power ba sed on the outer case temperature of the outer case in order to en...

Page 14: ...s cable voltage failure Turn off and restart E013 Inverter over load protection Reduce the load Restart AC E014 Inverter short circuit Correct the short circuit output Restart AC E015 Inverter cooling fan discharge over temperature protection Restart when the cooling fan temperature is lower E016 Inverter cooling fan temperature detector is not working Connect NTC and restart E017 PV input over vo...

Page 15: ...0 refer to the digital indicator display The battery icon indicates the battery status of total charge remaining KODAK PPS1800 can be used until it is empty but we recommend to recharge when the level is below 20 3 Can I charge the KODAK PPS1800 while supplying power at the same time Yes The AC output supports simultaneous charging and discharging Please note however that this only makes sense wit...

Page 16: ... 20 and 40 C 4 104 F Using the battery at temperatures outside the lower and upper limits reduces the battery s running time Do not connect a continuous load of more than 1000 W The unit s output stops automatically in case of overloading since it reduces the running time of the battery Do not continue to charge the battery after it has charged completely Pay attention to the indicated capacity Do...

Page 17: ...r workmanship please take the original sales receipt with purchase date invoice etc to the retail store In case of normal use the power supply unit will be repaired or replaced free of charge within the two year warranty period In additi on to that the customer must bear any shipping charges that may occur 2 The repair is not free of charge in the following cases even within the warranty period A ...

Page 18: ...nternational com USA Canada Delta Millenium Inc 216 Route 206 Suite 1 Hillsborough NJ 08844 USA Toll Free 888 765 5428 E Mail info digitalsupportdesk com AFRICA GBLT South Africa Unit 94 96 Allandale Business Park CNR Morkels Le Roux Halfway House Midrand Johannesburg South Africa Telephone 27 0 11 516 0001 E Mail sales gbt international co za 14 CUSTOMER SERVICE ...

Page 19: ...19 ...

Page 20: ... GmbH An Gut Nazareth 18A 52353 Düren Germany Phone 02421 20856 0 The Kodak trademark logo and trade dress are used under license from Kodak All information contained in this document is subject to change without notice ...

Reviews: