background image

Summary of Contents for FS-10-N

Page 1: ...PR JfCT R...

Page 2: ...tart if your Sound Kodascope is set up correctly and the instructions followed closely This manual is designed to help you do this quickly OPERATION MAINTENANCE Operational maintenance the things you...

Page 3: ...r to screen Whatever the limiting factor may be screen size lens focal length screen brightness or pro jector to screen distance the graph below will give you quickly the information you need to make...

Page 4: ...ward the audience The speaker case may be closed or left open Place the Kodascope case on a firm table with the front end flush with the edge lift the four latches and lower the two sides of the case...

Page 5: ...r spring belt over the larger reel arm pulley For smaller reels use the small pulley Press the SPRING CATCH raise and remove the LA MP HOUSING Insert the projection lamp into the SOCKET with the large...

Page 6: ...t may have to be altered slightly after the framing lever has been set in the proper position for the film Turn the control switch to OFF and turn the EXCITER LAMP CONTROL knob in a clockwise directio...

Page 7: ...back the pressure roller lever and insert the film over the sound loop roller Release the pressure roller lever Press dow on tb tension roller lever and place the film beneath the sound drum Thread t...

Page 8: ...cused on the sound track you will obtain brilliant reproduction of music and speech will be crisp and distinct After the fidelity lever has been set adjust the TONE and VOLUME controls in the conventi...

Page 9: ...p control knob until it clicks at the ON position Control volume with the VOLUME control knob Do not turn the VOLUME control up so for that the microphone howls or feeds back Microphone or Phonograph...

Page 10: ...m the housing and clean it in the same manner as the pro jection lens When replacing the condenser lens push it in as far as it will go and tighten the lock screw Clean the REFLECTOR without removing...

Page 11: ...the locating lug and slot to correctly position the shield Projection Lamp Follow the directions on page III to replace the projection lamp After installing a new lamp adjust for evenness of illumina...

Page 12: ...eplacing the upper spring belt push the rewind lever in so that the upper pulley will turn freely Feed the belt through the opening in the front of the Kodascope and between the two BELT GUiDES and th...

Page 13: ...e receptacle and remove the TONE and VOLUME control knobs from the operating side Re move the three AMPLIFIER SCREWS holding the amplifier to the platform and carefully withdraw the amplifier REMOVING...

Page 14: ...he blades bendinq toward the motor and tighten the setscrew against the flat of the shaft Replace the washer on the motor resistor bolt and tighten the nut ADJUSTING THE MOTOR SPEED At sound speed the...

Page 15: ...d attach the bracket loosely so that further adjust ment can be made 1 I ALIGNING THE SOUND PICKUP ROD CAUTION Avoid shock from high voltages do not touch any internal ports of the amplifier Move the...

Page 16: ...akage of air into the cell due to fine cracks in the glass envelope or a broken seal 2 Inspect sound rod for breakage or misalign ment See page XIII b If sound is not heard 1 Check grid clip on 6J7 tu...

Page 17: ...amperes 250 volts Projection Lamp Part No 54909 750 watt 115 volt T 12 medium prefocus base Exciter Lamp Part No 58260 Mazda C 4 volts 0 75 amperes 5 8 clear C 6 filament single contact prefocus base...

Page 18: ...EASTMAN KODAK COMPANY ROCHESTER4 N Y 3 52 GLP B L ithog aphed in the United States of Arne ica...

Page 19: ...L t I j...

Page 20: ......

Reviews: