Kobold KEL Series Installation And Operating Instructions Download Page 1

In order to obtain a fully developed flow profile through the 
instrument, the pipe run should be straight and should not 
contain any elbows bends or fittings. A free pipe run of 10-
15 times the pipe bore upstream and 5 times downstream 
of the meter is recommended. Hose connection with area 
reducing hose nipples, if desired, should be installed only 
after this run.

Filtration 

The meter can be installed in any orientation, but should 
not be installed with the diaphragm housing at the bottom 
of the pipe, since the housing may then function as a 
collection point for dirt. If there is a risk that the liquid may 
contain dirt particles which are larger than the pressure 
sensing ports, a filter must be installed in the system 
upstream of the meter.

Switchpoint Adjustment 

Unless otherwise specified on ordering, units are delivered 
with the switches adjusted so that one switch is set to the 
minimum flow value (“1” on adjusting dial) and one at 
maximum flow (“5” on the adjusting dial.) These values can 
be reset as follows: 

1. Undo the 2 screws which retain the cover on the top of 

the meter housing. This renders the adjusting dials 
accessible. 

2. The adjusting dials are marked 1 through 5. The 1 

through 5 indexing of the dial divides the flow 

measuring range into 5 equal parts. If it is desired to 
have a switchpoint at 50% of maximum flow the switch 
adjusting dial would be adjusted to 2.5, etc. An 
adjusting tool is included with the unit and is clipped 
inside the cover. Adjust the switchpoint with the 
adjusting tool. 

The wiring diagram above illustrates the switching status 

when the

 

flow is zero

.

Change of Measuring Range

The brass threaded and brass ANSI wafer units can have 
their measuring ranges easily modified in the field by 
simply replacing the measuring orifice and scale. To 
replace the orifice, undo the through bolts which clamp the 
meter between the flanges in the pipe work. Remove one 
of the spacer rings which hold the orifice flange in place. 
On the wafer style units, the spacer rings are fixed by 
means of 2 screws. Replace the orifice flange with a new 
one and then replace the spacer ring. Keep in mind that the 
measuring scale will also need to be replaced with one 
which has the correct new range on it. Stainless steel 
threaded and stainless steel wafer style units do not have 
interchangeable orifices. They require a new pipe section 
or wafer body in order to change the range.

Installation in Piping

KOBOLD Series KEL Installation and Operating Instructions

Manual-KEL_9-05

FM Rev. 9/13/05