Kobold HND-F105 Operating Instructions Manual Download Page 1

 
 

 

Operating Instructions 

for 

Manual Humidity Precision 

Measuring Unit 

 

Model: HND-F205 

 

 
 

Summary of Contents for HND-F105

Page 1: ...Operating Instructions for Manual Humidity Precision Measuring Unit Model HND F205...

Page 2: ...on of Logger 18 7 6 Output 21 8 Maintenance 22 8 1 Battery Operation 22 8 2 Fault and System Messages 23 8 3 Application in the glued timber construction acc to DIN 1052 1 MPA certified 23 8 4 Inspect...

Page 3: ...u wish the operating instructions can also be sent to you by post in paper form against an applicable postage fee The devices are only to be used maintained and serviced by persons familiar with these...

Page 4: ...tion may invalidate its warranty Therefore any resulting damage is not the responsibility of the manufacturer The user assumes all risk for such usage 5 Operating Principle The KOBOLD manual measuring...

Page 5: ...to connecting the plug power supply with the mains supply make sure that the operating voltage stated at the power supply is identical to the mains voltage Treat device and probes carefully Use only i...

Page 6: ...ase make sure the device temperature has adjusted to the ambient temperature before trying a new start up 3 The circuitry has to be designed most carefully if the device should be connected to other d...

Page 7: ...nate a possible risk of injury 7 1 2 Disposal Notice Dispense exhausted batteries at destined gathering places Send the device directly to us if it should be disposed We will dispose the device approp...

Page 8: ...ts 3 Moisture estimation Estimation of the material condition via top arrows DRY MEDIUM WET 4 Warning triangle Indicates low battery 5 u or w Displays unit moisture content u or wet basis moisture con...

Page 9: ...ogger functions refer to chapter 7 5 Operation of Logger Set Menu or temperature input confirming of selected input return to measure Key 3 During the measure shortly displaying temperature or changin...

Page 10: ...stable measuring result this will be frozen with HLD When pressing the store key a new measure will be initiated If logger is switched on Func CYCL Func Stor device works like setting would be auto HL...

Page 11: ...isture Measuring 7 3 1 Moisture Content u and Wet Basis Moisture Content w Depending on the Application one of the two units is necessary Carpenters joiners and the like commonly use the moisture cont...

Page 12: ...these characteristic curves is more than 3 Base for this statement is complex statistical surveys considered measuring range 7 25 This random error will not occur for the whole HND F series with the...

Page 13: ...nu Used temperature value Aux Display Atc on Temperature probe connected Temperature measuring through connected probe Display arrow T extern No temperature probe connected Device internal temperature...

Page 14: ...ut within the range of 6 to 30 Beyond this range the acquirable accuracy will lessen but the device will deliver reference values still sufficient for the practitioner Reciprocating piston electrode H...

Page 15: ...tion plays no role when using the building material measuring Measuring concrete with brush probe HND FF06 7 3 6 2 Soft Materials polystyrene or similar Measuring with measuring pikes or pins HND FF04...

Page 16: ...rried out from which the exact moisture content has to be dedicated with the Darr Probe or the CM Method The Results can be stored in the device with the help of the GMHKonfig Software and can be acce...

Page 17: ...operation is impossible 7 4 3 Individually Programmable Characteristic Curves There are 4 individually programmable characteristic curves integrated By using them there can be used other material curv...

Page 18: ...d auto hold functions are no longer available key 6 is solely used for the operation of the logger functions 7 5 1 Func Stor Storing Single Measurements Each time when store key 6 is pressed a measure...

Page 19: ...e Logger Cycle Time is selectable see Device Configuration For example CYCL 1 00 A measuring is recorded after each 60 seconds Special feature of this logger function The device will change to a sleep...

Page 20: ...the logger memory is full the display will show The recording automatically will be stopped Stopping the recording manually By pressing Store key 6 the recording can be stopped manually Then the follo...

Page 21: ...Interface functions The following standard software packages are available for data transfer BUS S20M 20 channel software to record and display the measuring values 1 2 Code Name Function 1 2 Code Na...

Page 22: ...C 0 then the device will apply 0 V to the output In case of an error Err 1 Err 2 no sensor etc the device will apply slightly above 1 V to the output Plug wiring Attention The 3rd contact has to be le...

Page 23: ...has discharged sensor broken or device defective return to manufacturer for repair Err 1 value exceeding measuring range check Is the value exceeding the measuring range specified temperature too high...

Page 24: ...ouple element NiCr Ni type K Measuring range humidity 0 0 to 100 weight moisture depending upon the respective material characteristic curve Temperature 40 0 200 0 C 40 0 392 0 F Accuracy at nominal t...

Page 25: ...Hold function freezing of the current value Auto hold autom freezing of a constant measured value Sort limitation of the material selection to max 8 favorites Automatic off function 1 120 min can be...

Page 26: ...10 Floating external NiCr Ni temperature probes HND FF11 Sensor for surface measurement of paper textiles etc HND FF12 Wood moisture set contents HND Z023 Z051 Z053 FF02 FF10 HND FF13 Wood and constru...

Page 27: ...nting of the data of housings of the HND series with logger function BUS S20M Software for recording measurement data on a computer for instruments of the HND series without logger function HND Z051 M...

Page 28: ...low EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements EN 50581 2012 Technical documentation for the assessment of electrical...

Page 29: ...n Hard Acronychia laevis h 28 5 66 Ayan Distemonanthus benthamianus h 285 7 54 Balau Shorea laevis h 31 4 54 Balau red Shorea guiso h 32 4 68 Balsa Ochroma pyramidale h 33 4 91 Basralocus Angelique Di...

Page 30: ...Cypress Northern Callitris intratropica h 115 6 78 Cypress Rottnest Island Callitris preisii h 116 7 80 Cypress White Callitris glaucophylla h 117 6 86 Dakua Salusalu Fiji Decussocarpus vitiensis h 1...

Page 31: ...leri h 243 8 73 Mahogany New Guinea Dysoxylum spp h 241 6 74 Mahogany Red Eucalyptus botryoides h 244 7 91 Mahogany Rose Dysoxylum fraseranum h 245 7 65 Mahogany Southern Eucalyptus botryoides h 246 5...

Page 32: ...e Celery Top Phyllocladus aspenifolius h 329 7 71 Pine Hoop Araucaria cunninghamii h 330 7 79 Pine Huon Dacrydium franklinii h 331 8 70 Pine King William Athrotaxis selaginoides h 332 7 67 Pine Klinki...

Page 33: ...atopetalum succirubrum h 408 7 63 Tallowwood Eucalyptus microcorsis h 409 4 92 Tatajuba Bagassa guianesis h 30 7 44 Taun Maleisien Pometia pinnata h 195 0 105 Taun New Guinea Pometia pinnata h 196 6 1...

Page 34: ...7 yes Plaster synthetic b 12 18 2 60 8 yes On wall plaster b 20 0 0 38 8 no Lime mortar KM 1 3 b 14 0 4 40 4 yes Lime sand bricks 14 DF 200 gross density 1 9 b 28 0 1 12 5 yes Limestone b 15 0 4 29 5...