background image

8238-129

th

 Street, Surrey, B.C. Canada V3W 0A6 

 

 

         

 

Telephone 604-572-3935           Fax 604-590-8313 

   

  http://www.kobelt.com 

 

“Leaders in Quality Marine Controls, Steering Gear, and Disc Brakes.” 

 

 

 
 

   

 

     

       

      

       

 

 
 
 
 
 
 
 
 
 
 
 

7173-KAS     MANUAL

 

 
 
 
 

February 2012

 

Summary of Contents for 7173-KAS

Page 1: ...8238 129th Street Surrey B C Canada V3W 0A6 Telephone 604 572 3935 Fax 604 590 8313 http www kobelt com Leaders in Quality Marine Controls Steering Gear and Disc Brakes 7173 KAS MANUAL February 2012...

Page 2: ...E SPEED STEERING SYSTEM BLOCK DIAGRAM 401706 2 SINGLE SPEED STEERING SYSTEM WIRING DIAGRAM 401706 3 DUAL RATE SPEED STEERING SYSTEM BLOCK DIAGRAM 401706 4 DUAL RATE SPEED STEERING SYSTEM WIRING DIAGRA...

Page 3: ...installed on the pump starting panel capable of turning off the 7173 and associated components If more than one full follow up control unit is used in a given system a station transfer system is requi...

Page 4: ...environment The Model 7173 KAS is a multi optional driver board working on 12 or 24 Volt DC In the event of feedback potentiometer failure or wire break the board will act in fail in mode An LED ligh...

Page 5: ...MODEL 7173 KAS Dimensions are in inches mm TYPICAL MULTIPLE STATION ARRANGEMENT...

Page 6: ...ounted inside a waterproof housing The housing should be mounted in a convenient easily serviced location Allow enough space to permit opening of the housing cover see Model 7173 KAS data sheet Mounti...

Page 7: ...RTANT Hydraulic steering gears using a hydraulic Full Follow Up System often referred to as Telemotor or Accumotor must drive the Feedback Unit from the Servo Cylinder not the Rudder stock In such a c...

Page 8: ...le should be used for the Controller If more than one controller is used a Station Select switch must be connected between the controller and the Model 7173 KAS The Station Select switch is optionally...

Page 9: ...rse the black and white wires coming from the controller 7 Repeat step 6 for any additional controllers wired via a station selector 8 Move the FFU controller to a hardover position and adjust the int...

Page 10: ...eplace repair repair or replace repair reverse wires reverse wires Rudder does not travel same number of degrees hardover to hardover control potentiometer not centered feedback unit or potentiometer...

Page 11: ...operation 4 Apply lubricating oil grease to mechanical parts at all available greasing points Make sure that no oil or grease will come into contact with any electronic parts For gears and rotating sh...