3329 Manual
KOBELT MANUFACTURING CO. LTD
Rev A
MNL-3329.docx
12
5.3
S
EAL
S
ERVICE
All sliding seals should be lubricated with oring grease once every two years. When replacing seals,
ensure both U-cups are oriented correctly (refer to fig6 below).
Figure 6: Seal Orientation
5.4
R
ECOMMENDED
S
PARE
P
ARTS AND
K
ITS
The spare parts kept on hand will depend on the severity of the service. The User should monitor the
condition of their control head to predict necessary spare parts and ensure they are on hand when
needed. As a minimum Kobelt recommends keeping the following parts for each unit in service:
1.
One
3329-RK
repair kit
2.
One solenoid for 7048-0019 valve
3.
One solenoid for 7048-0020 valve
Refer to the parts list drawings in
for a complete list of parts. When purchasing spare parts
refer to Appendix B: Parts List at the back of this manual for Kobelt component Part Numbers.
It is recommended that any required service work on a
Kobelt unit be performed by a factory authorized service
representative. Please contact the nearest Kobelt authorized
distributor for assistance.