Page 1: ...Kobe NO Monteringsanvisning 2 Installation manual 4 GB Art no FP KOB00 000 Last updated 27 11 2013 kg...

Page 2: ...egnet sparkelmasse Mindre s r og ujevnheter sparkles Dersom s ret er dypt eller det er en st rre skade anbefales det sparkle i flere omganger med fliselim eller sementsparkel for unng synk Jevn til me...

Page 3: ...sisjon til r ykinnf ringen Merk ogs opp eventuelt hull til friskluftsett gjennom gulv ekstrautstyr Friskluftstilf rsel ekstrautstyr NB Produktet kan kun kobles til friskluftsettet gjennom de prefabrik...

Page 4: ...and sand with a suitable filler Minor damage and uneven surfaces can be filled If the damage is deep or in the event of significant damage you are recommended to fill repeatedly with tile adhesive or...

Page 5: ...the chimney Distortions in floors and walls may influence the height Dry stack the fireplace for accurate height and positioning of the flue chimney connection If a fresh air supply set accessory is...

Page 6: ...8 10 mm 13 mm 24 mm 2 5 mm 4 mm 5 mm Du trenger f lgende verkt y NO GB You need the following tools 3 mm Tarvitset seuraavat ty kalut Du beh ver f jande verktyg SE FI...

Page 7: ...9 Kobe mm FIG 1A 1430 1340 325 630 635 255 420 1090...

Page 8: ...10 630 370 244 190 595 835 325 1005 595 835 595 680 Kobe mm FIG 1B...

Page 9: ...11 mm AIR Kobe 347 587 173 347 587 242...

Page 10: ...12 mm AIR II Kobe 347 587 173 347 587 242 120 140mm 120 170mm 90...

Page 11: ...13 Brannmur Brandmur Palomuuri Firewall Brennbart materiale Br ndbart materiale Br nnbart material Tulenarka materiaali Combustible material FIG 2 400 600...

Page 12: ...til tilluft m elementene klargj res for dette f r montering Se m ltegning Kobe AIR for m l Assembly FIG 3A Kobe is delivered standard with parts shown in FIG 3A This allows all combinations shown in F...

Page 13: ...15 FIG 3B FIG 3A...

Page 14: ...16 FIG 4B FIG 4A...

Page 15: ...17 FIG 4C...

Page 16: ...ementet som skal holde innsatsen Vatre elementet og bruk medf lgende akryl for lime elementene sammen FIG 5 After assembling the desired base place the element supporting the insert Use acrylic glue b...

Page 17: ...sen leveres standard med lange ben De korte bena ligger i forsendelsen med omrammingen FIG 6 7 Remove the rear radiation shield from the insert place the insert on it s back Fit and ajust the shortser...

Page 18: ...nnsatsen l ftes i st ende stilling Ikke tipp innsatsen tilbake i st ende stilling da adapter og bein kan ta skade av dette FIG 7 If the insert is to be connected to a extra air supply fit the added ad...

Page 19: ...akover og fortsett monteringen fra FIG 11 FIG 8 If the insert is to be connected through the back plate of Kobe the back plate needs to be prepared for this before assembly Make sure to remove the cor...

Page 20: ...s det er penrom mellom flaten p gjennomf ringselementet og pipen skal dette tettes Chimney Pipe Adapter The added chimney pipe adapter MUST be used between the back side of the product and the chimney...

Page 21: ...g gjennomf ringselementet om produktet monteres mot tilst tende vegger i brennbart materiale FIG 10 Place the back plate into the element supporting the insert Attention Make sure to seal the gap betw...

Page 22: ...varmeskjoldet og flytt r ykstussen Se innsatsens manual for detaljer FIG 11 Place the insert in to the supporting element If the insert is going to be connected through the top outlet place the rear r...

Page 23: ...oppheting Dette penrommet skal IKKE blokkeres eller tildekkes p noen m te FIG 12 Place the next element Use acrylic glue between the elements Makre sure there is a small gap between the element and th...

Page 24: ...at det er 2 3mm avstand mellom innsatsen og betongelementene da innsatsen ekspanderer under fyring FIG 13 Place the next element Use acrylic glue between the elements Makre sure there is a small gap...

Page 25: ...det er 2 3mm avstand mellom innsatsen og betongelementene da innsatsen ekspanderer under fyring FIG 14 Place the next element Use acrylic glue between the elements Make sure there is a small gap 2 3m...

Page 26: ...mentene da innsatsen ekspanderer under fyring Se FIG A for korrekt plassering av sideelementene FIG 15 Place the next element Use acrylic glue between the elements Makre sure there is a small gap betw...

Page 27: ...eskjoldene Om innsatsen skal kobles til gjennom bakplaten fjern utsparingen i varmeskjoldene f r disse monteres FIG 16 Place the rear radiation shields If the insert is connected through the back wall...

Page 28: ...30 FIG 17 FIG 17 Plasser det fremre varmeskjoldet FIG 17 Place the front radiation shield...

Page 29: ...31 FIG 18 FIG 18 Plasser det verste elementet Bruk akryllim mellom elementene FIG 18 Place the top concrete element Use acrylic glue between the elements Acryl Acryl kg...

Page 30: ...lime sideristen p plass NB Sideristen skal ikke under noen omstendighet blokkeres eller dekkes til FIG 19 Place the top plates and grate Use acrylic glue between the concrete elements Use acrylig clu...

Page 31: ...sikre at riktig glassilegg blir brukt kontroller pakklisten Glassileggene limes med medf lgende akryl FIG 20 Kobe is delivered with two combinations of decorative glass depending on left right placeme...

Page 32: ...at det blir en tydelig fordypning mellom elementene FIG Z Once the fireplace is assembled fill the joints with acrylic and even them out with a sponge or finger and some soapy water in order to have a...