INSTALLATION INSTRUCTIONS 

AND OPERATION MANUAL

Summary of Contents for RAX9530SQB-1

Page 1: ...r RAX9530SQB DC 1 30 RAX9536SQB 1 or RAX9536SQB DC 1 36 RAX9542SQB 1 or RAX9542SQB DC 1 42 RAX9548SQB 1 or RAX9548SQB DC 1 48 RAX9530SQB DC24 1 30 RAX9536SQB DC24 1 36 RAX9542SQB DC24 1 42 RAX9548SQB DC24 1 48 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ...EP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shipping damages cosmetic damages or defects 4 For all other issues call 1 877 BUY KOBE 289 5623 or e mail to info koberangehoods com NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEEN INSTALLED 2 KNOCK OUT HOLES HAVE BEEN PU...

Page 3: ...CE 9 SPECIFICATIONS 10 MEASUREMENTS DIAGRAMS 12 PARTS LIST 13 CIRCUIT DIAGRAM 16 TROUBLE SHOOTING 17 WARRANTY 18 WARRANTY INFORMATION FORM 20 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Page 4: ...treatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range h...

Page 5: ...s If you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufactu...

Page 6: ... H Screws Package I Hood Mounting Bracket J Screws Package K Duct Cover Model No RA02DC 1 L Wire Cap M Screws Package A B C D E F G H I J K L M Extension Duct Cover Box Included in RAX95 SQB DC24 1 Only N Extension Duct Cover Model No RA02DC 24 1 O Duct Cover Mounting Bracket P Screws Package N O P FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www koberangehoods com OR CONTACT KOBE RANGE HOODS AT ...

Page 7: ...loor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom 30 36 Hood Recommended 27 to 30 42 48 Hood Recommended 30 to 36 A B D E D Height of Hood E Height of Duct Cover SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAG...

Page 8: ...ay reduce the performance of the hood Temporarily wire the hood to test for proper operation before installing Important Peel protective film off the hood and the duct cover if any If necessary prepare back wall frame with cross framing lumber for secure installation Refer to Table 1 and measurements on Page 12 to decide the level of the lumber Figure 2 Loosen hood mounting brackets at the back of...

Page 9: ...ower Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 5 Connect the electrical wires Connect three wires b...

Page 10: ...crews included to attach duct cover to hood Refer to Figure 6 Install Accessories 8 Attach oil tunnel Refer to Figure 7 9 Refer to Figure 8 Slide the baffle filter into the hood Push the baffle filter upward Slide forward Pull downward Fit into place 10 Repeat until all baffle filters and spacers are resting against oil tunnel Refer to Figure 8 Final Assembly 11 Turn power ON in control panel Chec...

Page 11: ...t Control Speed Control Refer to Figure 9 Figure 9 Note For best results turn hood to QuietMode prior to preparation or cooking to establish airflow in the kitchen Adjust speed as needed Rotate the Speed Control clockwise to cycle from QuietMode Low High and off and rotate counterclockwise to cycle from High Low QuietMode and off Rotate the Light Control clockwise to turn on the light ...

Page 12: ...slightly damp towel to get rid of any cleaning solution Use dry soft towel to dry the hood 3 To bring the glow back into a stainless steel finish use a stainless steel cleaner 4 DO NOT allow deposits to remain for long periods of time 5 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust 6 DO NOT allow salt solutions disinfectants bleaches or ...

Page 13: ...9536SQB DC24 1 320W 2 86A RAX9542SQB DC24 1 350W 3A RAX9548SQB DC24 1 350W 3A VOLTAGE 120V 60Hz NUMBER OF BLOWER 1 30 36 2 42 48 DESIGN 18 Gauge Seamless Satin Finish FAN TYPE CENTRIFUGAL Squirrel Cage EXHAUST Top 6 Round 30 36 Top 8 Round 42 48 CONTROLS Rotary Switch LIGHTS 3 Watt LED x 2 30 36 3 Watt LED x 3 42 48 HOOD DIMENSION W x D x H RAX9530SQB 1 RAX9530SQB DC 1 RAX9530SQB DC24 1 29 3 4 x 2...

Page 14: ...R RAX9530SQB DC 1 RAX9536SQB DC 1 RAX9530SQB DC24 1 RAX9536SQB DC24 1 Air Capacity cfm 300 580 760 Sone 1 8 4 7 5 4 DUAL BLOWERS RAX9542SQB DC 1 RAX9548SQB DC 1 RAX9542SQB DC24 1 RAX9548SQB DC24 1 Air Capacity cfm 450 800 1200 Sone 2 5 6 0 8 0 One sone is equivalent to the sound of a refrigerator at 40 decibels Specifications subject to change without notice ...

Page 15: ...s are converted from millimeters Inch measurements are estimated MODEL NO RAX9530SQB 1 or RAX9530SQB DC 1 30 RAX9536SQB 1 or RAX9536SQB DC 1 36 RAX9542SQB 1 or RAX9542SQB DC 1 42 RAX9548SQB 1 or RAX9548SQB DC 1 48 Duct Cover for RAX95 SQB DC24 1 Series Baffle Filter for RAX95 Series ...

Page 16: ... RAX9542SQB 1 B101 9142 14A Metal Oil Tunnel RAX9548SQB 1 B101 9148 14A 7 Light Panel RAX9530SQB 1 B101 9530 06 RAX9536SQB 1 B101 9536 06 RAX9542SQB 1 B101 9542 06 RAX9548SQB 1 B101 9548 06 8 Motor RAX9530SQB 1 RAX9536SQB 1 L1 0302 0120 802RO RAX9542SQB 1 RAX9548SQB 1 L1 0302 0120 802 RE 9 Capacitor x 1PCS RAX9530SQB 1 RAX9536SQB 1 L1 0401 0120 24 Capacitor x 2PCS RAX9542SQB 1 RAX9548SQB 1 L1 0401...

Page 17: ...14 MODEL NO RAX9530SQB 1 or RAX9530SQB DC 1 and RAX9530SQB DC24 1 30 RAX9536SQB 1 or RAX9536SQB DC 1 and RAX9536SQB DC24 1 36 ...

Page 18: ...15 MODEL NO RAX9542SQB 1 or RAX9542SQB DC 1 and RAX9542SQB DC24 1 42 RAX9548SQB 1 or RAX9548SQB DC 1 and RAX9548SQB DC24 1 48 ...

Page 19: ...9530SQB 1 or RAX9530SQB DC 1 and RAX9530SQB DC24 1 30 RAX9536SQB 1 or RAX9536SQB DC 1 and RAX9536SQB DC24 1 36 MODEL NO RAX9542SQB 1 or RAX9542SQB DC 1 and RAX9542SQB DC24 1 42 RAX9548SQB 1 or RAX9548SQB DC 1 and RAX9548SQB DC24 1 48 ...

Page 20: ... continuity from light transformer to LED light housing s Light transformer is defective Check power input and power output on the light transformer If it s needed replace the light transformer The control panel is defective Replace the control panel The range hood is not venting out correctly The range hood is installed outside of the manufacture recommended clearance Adjust the clearance between...

Page 21: ...ich include but are not limited to Service technician travel charges if the requested service location is 30 miles out of KOBE s authorized service area Parts shipping expenses Un installation of defective product and Installation of replacement product Warranty Exclusions This warranty does not cover including but not limited to the following a Improper installation b Any repair alteration modifi...

Page 22: ...lify for warranty service you must 1 Have the ORIGINAL proof of purchase 2 Be the ORIGINAL purchaser of the product 3 Have the model number 4 Have the serial number 5 Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER KOBE SERVICE CENTER USA ONLY Toll Free 1 855 800 KOBE 5623 E mail kobe adcoservice c...

Page 23: ...vice purpose 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com For service in Canada and to report a problem please contact Tel 1 626 775 8880 Email customer service koberangehoods com Your notes ...

Page 24: ... utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el extran...