Programming/encoding of bed guard 

 
The bed mat is placed in the bed under the sheet or bed mattress and connected to TX901 transmitter. 
You can attach the bed mat with tape, so that it does not move. 
 
CT901R is placed in an electrical socket and MK204 relay cable is connected to the existing alarm system.  
The clock and any light must be set if you wish to use it. 
 

Co-encoding of TX901 and CT901R 

Select "Main menu" => "Transmitters" => "Learn new" press Ent and activate the bed mat. 
 
Then you can choose different settings: 

 

Light: move the green arrow downwards to " No light " and press Ent. Then use the arrow buttons to change the 
value. 
The "No light" light never comes on. 
"Light, time" means that the light turns on in the time period selected in Time Control, page 6. 
"Light, always" the light is always on when the user leaves the bed. 
The menu can also be accessed under "Main menu" => "Transmitters" 
 
Bed, timer:  
Here you can set how long the user can be out of bed before the bed alarm sounds. 

 

Move the green arrow to "Bed, timer" and press Ent. 
Select the value with the arrow buttons and confirm with Ent. 
Return to the Start menu by pressing Esc. 
 
 

 

 

Sender nr. 1 

TX-900-1 

Batt.: 2.83V

 

  Bed guard 

 Light, time 

 Alarm, time: 2 

 

Sender  nr. 1 

 Bed guard 

  Light, time 

 Alarm, time: 2 

 Bed, timer 

 

Bedtimes      

 

Summary of Contents for CT901-BED

Page 1: ...OP Elektronik A S Fabriksvej 20 DK 7600 Struer knop knop dk knop dk 45 97840444 THIS MANUAL APPLIES TO THE SOFTWARE VERSION 3 X User manual for CT901 BED Contains CT901R TX901 D4106011A_8pin Relay cab...

Page 2: ...ck 4 Setting the light 5 Time management 6 Switching off the device 7 Log history 7 Programming encoding of bed guard 8 Co encoding of TX901 and CT901R 8 System test 9 Voltage drop of 230 Vac 9 Bad or...

Page 3: ...2 Place CT901R control unit in a wall socket so that it lights up 3 Connect the relay cable to the control unit and to the existing alarm system Points 4 to 8 are factory set if the units are purchase...

Page 4: ...and down with the green arrow buttons A menu line is selected with shows the active row at the bottom of the screen indicates that you can scroll further down at the top of the screen indicates that...

Page 5: ...ight slave LS901 If you wish to use the CT901R to light up an apartment e g when a patient gets up at night you can place up to 5 additional light slaves in different rooms all of which light up when...

Page 6: ...r can go to bed and rest in the middle of the day without the light and alarm being activated when the person gets up If time control is not activated the light is switched on and the alarm is activat...

Page 7: ...g It shows a list of the last 100 events with type time and date The last line shows Delete log select the line with and press to delete the log Types of activities S Bed guard alarm t Have been out o...

Page 8: ...an choose different settings Light move the green arrow downwards to No light and press Ent Then use the arrow buttons to change the value The No light light never comes on Light time means that the l...

Page 9: ...multiple error messages scroll with the up down arrow The system tests the following elements Voltage drop of 230 Vac Bad or no battery in CT901R and encoded LS901 units Bad battery in encoded Transmi...

Page 10: ...rce LED adjustable from 0 100 Approx 100 lumen max Lightslaves Connection of 5 additional LS901 light slaves wirelessly Sender Encoding of 1st transmitter in Knop s 900 901 series Log history Saves th...