2.8.3 Preparing to Connect
Input
Note:
Captive cables with a cross-section of 1.5 mm
2
are pre-installed in the P45***K2*1* order
version. These cables are 2 m long and can be shortened to the length required for the application.
Input cables, product variant P45***K1*0*
Temperature resistance
min. 100 °C (212 °F)
Maximum cable cross-section
16 mm
2
Minimum cable cross-section
1.5 mm
2
Maximum length of cable lug
21 mm from center of screw hole
Cable lug orientation
Vertical, ±10°
Cable lug material
Steel, tin-plated
Phillips screwdriver material
Steel, stainless
Output Cables/Power Supply
Note:
Use ferrules with a metal sleeve length of 10 mm or, for rigid cables, remove 10 mm of the
insulation at the cable ends.
Cable push-in terminal or screw terminal
Maximum cable cross-section
2.5 mm
2
Minimum cable cross-section
0.2 mm
2
2.8.4 Electrical Connection
The polarity of the inputs is indicated on the side nameplate.
In the case of the P45***K2*1* variant, red rings at both cable ends also indicate the positive pole.
Reverse polarity protection
The connection of the supply voltage/power supply at the output is protected against polarity
reversal. The product is not operational as long as the polarity is reversed.
Summary of Contents for P45000