background image

Safety 

 

Diaphragm Pumps N 035.18 

Translation of original Operating Instructions, english, KNF 121228-121398 04/14 

The pumps conform to the Directive 2011/65/EU (RoHS2). 

The pumps conform to the safety regulations of the EC Directive 
2004/108/EG concerning Electromagnetic Compatibility and the 
EC Directive 2006/42/EG concerning Machinery. 

The following harmonized standards have been used: 

IP20 

IP44 

DIN EN 55014-1/2 

DIN EN 55014-1/2 

DIN EN 61000-3-2/3 

DIN EN 61000-3-2/3 

DIN EN 60335-1 

DIN EN 60204-1 

 

Tab. 2

 

Only have repairs to the pump carried out by the KNF Customer 
Service responsible. 

Only authorized personnel should open those parts of the housing 
that contain live electrical parts. 

Use only genuine parts from KNF for servicing work. 

Standards 

Customer service and  

repairs 

Summary of Contents for N035 AN.18

Page 1: ...35 1 2 AV 18 N035 3 AN 18 N035 3 AT 18 N035 3 AV 18 KNF Neuberger GmbH Alter Weg 3 79112 Freiburg Germany Phone 49 0 7664 5909 0 Fax 49 0 7664 5909 99 E Mail info knf de www knf de Contents Page 1 Abo...

Page 2: ......

Page 3: ...arning is located here Possible consequences of a failure to observe the warning are specified here The signal word e g Warning indicates the danger level Measures for avoiding the danger and its cons...

Page 4: ...be trans ferred danger free in the specific application case Before using a medium check the compatibility of the materials of the pump head diaphragm and valves with the medium Only transfer gases wh...

Page 5: ...icker see fig 1 only after separating mains plug from power source When transferring dangerous media observe the safety regula tions when handling these media Be aware that the pumps are not designed...

Page 6: ...he EC Directive 2006 42 EG concerning Machinery The following harmonized standards have been used IP20 IP44 DIN EN 55014 1 2 DIN EN 55014 1 2 DIN EN 61000 3 2 3 DIN EN 61000 3 2 3 DIN EN 60335 1 DIN E...

Page 7: ...Aluminium PTFE coated Stainless steel FPM N 035 1 2 AT 18 N 035 3 AT 18 N 035 AV 18 Aluminium FPM Stainless steel FPM N 035 1 2 AV 18 N 035 3 AV 18 Tab 3 Pneumatic Values Pump type Delivery rate at a...

Page 8: ...5 3 AN 18 IP 20 100 50 60 300 3 5 N 035 3 AT 18 IP 20 N 035 3 AV 18 IP 20 N 035 3 AN 18 IP 44 100 50 60 360 4 8 N 035 3 AT 18 IP 44 N 035 3 AV 18 IP 44 Tab 5 see type plate Electrical Data 115 V versi...

Page 9: ...35 AN 18 IP 44 230 50 230 1 7 N 035 AT 18 IP 44 N 035 AV 18 IP 44 N 035 1 2 AN 18 IP 20 230 50 300 1 55 N 035 1 2 AT 18 IP 20 N 035 1 2 AV 18 IP 20 N 035 1 2 AN 18 IP 44 230 50 320 1 9 N 035 1 2 AT 18...

Page 10: ...nt relative humidity 80 for temperatures up to 31 C decreasing linear ly to 50 at 40 C Max altitude of site m above sea level 2000 Maximum permitted mains voltage fluctuations 10 Weight N 035 A_ 18 kg...

Page 11: ...ign and Function Design N 035 A_ 18 1 Pneumatic pump outlet 2 Pneumatic pump inlet 3 On Off Switch 4 Handle Fig 2 Diaphragm Pump N 035 AN 18 Design N 035 1 2 A_ 18 1 Pneumatic pump outlet 2 Pneumatic...

Page 12: ...2 Inlet valve 3 Transfer chamber 4 Diaphragm 5 Eccentric 6 Connecting rod 7 Pump drive Fig 5 Pump head The pump transfers compresses depending on pump version and evacuates gases and vapors The elast...

Page 13: ...connect components to the pump which are designed for the pneumatic data of the pump see section 4 If the pump is used as a vacuum pump safely discharge the pump exhaust at the pump s pneumatic outlet...

Page 14: ...head bursting due to excessive pressure increase Do not exceed max permissible operating pressure see section 4 Monitor pressure during operation If the pressure exceeds the maximum permissi ble oper...

Page 15: ...power 7 3 Switching pump on and off Switching pump on The pump may not start up against pressure or vacuum during switch on This also applies in operation following a brief power failure If a pump st...

Page 16: ...es Silencer filter ac cessory Change if it is dirty Tab 10 8 2 Cleaning When cleaning make sure that no liquids enter the inside of the housing 8 2 1 Flushing Pump Before switching off the pump flush...

Page 17: ...6 Quantity Tools Material 1 Allen key 3 mm 1 Allen key 4 mm 1 Allen key 5 mm 1 Screwdriver blade width 6 5 1 Screwdriver blade width 4 0 1 Fork wrench 16 mm only for two headed pumps 1 Pencil Tab 12...

Page 18: ...on and pull off the tube 3 Mark the position of the diaphragm head C in relation of the housing A with a pencil 4 Loosen the four allen screws B and remove the diaphragm head C 5 Unscrew the countersu...

Page 19: ...he cover plate T with a new gasket V and tighten the allen screws S 11 Place the diaphragm head C according to the marks made previously and tighten the screws B uniformly and diagonally torque 10 0 N...

Page 20: ...hragm and reed valves valve plate see Section 8 3 Tab 13 Flow rate pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet Cause Fault remedy...

Page 21: ...mp to mains power No voltage in the power source Check room fuse and switch on if necessary Tab 15 Pump is switched on but does not run the on off switch on the pump is lit Cause Cause The thermal swi...

Page 22: ...No Diaphragm F 001406 Countersunk screw D 110711 Reed valve M P 001328 Gasket V 011796 Tab 18 According to Fig 6 N 035 AV 18 N 035 1 2 AV 18 N 035 3 AV 18 Spare part Position Order No Diaphragm F 001...

Page 23: ...clearance and decontamination form For optimal processing of a return a copy of this declaration should be sent in advance via e mail regular mail or fax to KNF Customer Service refer to final page fo...

Page 24: ...nd safety clearance and decontamination form Diaphragm Pumps N 035 18 24 Translation of original Operating Instructions English KNF 121228 121398 04 14 12 Health and safety clearance and decon taminat...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...s Shinkawa Bldg Annex 3F 1 16 14 Shinkawa Chuo ku Tokyo Japan 104 0033 Tel 0081 0 3 3551 7931 Fax 0081 0 3 3551 7932 E mail info knf co jp www knf co jp Korea KNF Neuberger Ltd Woosan Bldg RM 202 336...

Reviews: