Installation and connection
Diaphragm vacuum pump N 89/N 811/N 814/N 815
16
Translation of original Operating and Installation Instructions, english, KNF 121242-121509 04/20
Fig. 8: Mounting dimensions pump series N 815 K_DC (All dimensional
tolerances conform to DIN ISO 2768-1, Tolerance Class V)
WARNING
Danger of burns from hot surfaces
Hot surfaces may be caused by overheating of the
pump.
Install the pump so that the motor fan can intake
sufficient cooling air.
When installing, make sure that there are no combustible or
thermally malleable objects placed in the immediate ambient of
the hot pump parts (head, motor).
Make sure that the installation location is dry and the pump is
protected against rain, splash, hose and drip water as well as
other pollutions.
Make sure, that the installation location is accessible for
maintenance and service.
Install the pump at the highest point in the system to prevent
condensate from collecting in the pump head.
Protect the pump from dust.
Protect the pump from vibrations and jolts.
For pumps with fan: Install the pump so that accidental finger
contact with the fan is impossible.
Cooling air supply
Immediate ambient of the hot
pump parts
Installation location