Operating Instructions LIQUIPORT EN
Installation and initial start-up
KNF Flodos | BA_LIQUIPORT_EN_11_153820.docx | Translation of original operating instructions, English
27
6.2 Installation
Before installation, store the pump at the installation location to bring it
up to ambient temperature.
NOTE
For problem-free, safe operation the following instructions should be
followed:
-
Install in a dry place.
-
Protect the installation location of the pump from water in the
form of rain, spray, splashes and drips.
-
Do not operate the pump in an aggressive or flammable envi-
ronment.
-
Choose a safe location (a level, flat surface) for the pump.
-
If the stability of the pump cannot be ensured, fasten the
pump in place using two screws.
-
Make sure that the hose connections can be fitted without
strain on the hoses.
-
Protect the pump against shocks, impacts and strong vibra-
tions.
6.2.1 Connect mains plug
DANGER
Risk of electric shock
-
Only operate the pump with the power supply unit supplied.
-
Connect the cable from the mains plug to the pump's power
supply socket.
-
Plug the mains plug into a correctly installed and properly
earthed mains socket.
-
Ensure that the mains plug is protected from water splashes.
-
Do not open pump housing or power supply unit.
-
Disconnect pump from power supply during maintenance
work.
-
If pump is installed permanently, fit a maintenance switch.
When connecting the device to a power source, the relevant norms, di-
rectives, regulations and technical standards must be observed.
Use suitable adapters in the power supply unit
Connect power supply unit to pump
Fig. 11: Electrical connection
Summary of Contents for LIQUIPORT 1.100