Designated use  

 The pump is exclusively intended for 

transferring liquids and gases. 

 Only install and operate the pump under 

the operating parameters and conditions 
described in the operating manual 

 

 Before using a medium, check 

whether the medium can be transferred 
danger-free in the specific application case. 

 Before using a medium, check the 

compatibility of the materials of the pump  
head, structured diaphragm and valves with 
the medium

.

 

 Only transfer liquids and gases which 

remain stable under the pressures and 
temperatures occurring in the pump.

 

 Laboratory equipment or additional 

components connected to a pump have to 
be suitable for use with the pneumatic 
capabilities of the pump (see type plate). 

 Observe the accident prevention and 

safety regulations

.

 

 Make sure that only trained and 

instructed personnel use the pump. 

Non designated use 

 

Caution 

The pump may not be 
operated in an explosive 
atmosphere.

 

 

 

 

Caution 

Checking if this pump can 
be used for the medical or 
food industry lies in the 
responsibility of the users. 

Operation  

 

 

Caution  

Before switching the pump 
on please observe the 
following points:

 

 All hoses are properly attached 

 Specifications of the power  

supply correspond with the data on the 
pump’s type plate. 

 The pump outlet is not closed or con-

stricted. 

 Do not exceed max. permissible 

operating pressure (see type plate). 

 Make sure the temperature of the 

medium is always sufficiently 
below the ignition temperature of 
the medium, to avoid ignition or 
explosion. This also applies for unusual 
operational situations. 

Taking the pump out of  
service 

 Ensure the pump is stopped, 

open pressure and suction lines to normal 
atmospheric pressure. 

 When transferring aggressive media, 

flush the pump out. 

 

Caution 

Observe following 
instructions 

SIMDOS

® 

10 

 

Quick Instructions 

 
The pump is delivered ready for use. 
 
These Quick Instructions summarises all the important 
points of the Operating instructions. 
 
For your own safety please read these instructions 
before using the pump. 
 
 

KNF FLODOS AG 

Wassermatte 2,             6210 Sursee,           Switzerland 
Tel   +41 (0)41 925 00 25       Fax   +41 (0)41 925 00 35 
www.knflab.com   www.knf-flodos.ch [email protected]

 

KNF Flodos reserve

s  t

he right

 to

 make technical chan

ges .

 - 

10/

2009 - I

D160046 

 

1.  Connect tubing 

 
1.  Ensure that the end of the tubing is 

cleanly cut 

2.  Place the compression ring and 

then the clamp ring over the tubing 

3.  Push the tubing firmly over the 

fitting 

4.  Secure the compression ring –

hand tight 

2.  Connect power supply 

 

 
 

3.  Turn on /Turn off 

 

 

4.  Start /  Pause 

 

 

5.  Stop 

 

Hold for 2 
seconds 

Press stop twice t
reset the counter 

 

Reviews: