background image

13

Cleaning

•  Pull the mains plug out of the socket 

before cleaning.

•  Wipe the device surfaces with a 

slightly damp cloth. For heavier soi

-

ling, use neutral soap and water.

•  Clean all glass panes and glass dis-

plays with a soft cotton cloth or a 

highly absorbent sponge cloth, a 

glass squeegee and a dry cotton 

cloth to wipe dry. Here, too, only use 

water and a neutral cleaning agent 

(pH5-7) for heavy soiling.

After cleaning with detergents, wipe all 

cleaned surfaces with clear water and 

remove all residues of the detergent 

from all surfaces of the freshness cooler. 

Remaining cleaning agent residues can 

damage the material over time and im-

pair the function of the device parts. Dry 

all cleaned surfaces.

Never clean with:

• 

Rubbing, scouring or chemically 

aggressive cleaning agents with a 

strongly acidic pH value of less than 

4 or a strongly alkaline pH value of 

more than 8

• 

microfiber cloths

•  Hard or sharp metal objects (e.g. 

glass plane, glass blade, steel wool)

•  Steam or high-pressure cleaner.

Defrost

The freshness cooler is equipped with 

an automatic defrosting system that 

works on the principle of so-called „hot 

gas defrosting“. It is therefore usually not 

necessary to defrost the freshness cooler 

manually. The start time of the automatic 

defrosting process is preset at the facto-

ry. In exceptional cases, it may be ne

-

cessary to defrost the cooler manually, 

e.g. due to a fault, improper installation, 

overloading, after cleaning or due to 

other sources of interference. The way 

you do this depends on whether your 

freshness cooler is connected to a wurm 

system or not

.

Defrosting devices without a bus con-

nection

Disconnect the freshness cooler from the 

power supply by pulling the mains plug 

out of the socket.
•  Wait about a minute.
•  Reconnect the freshness cooler to the 

power supply by inserting the mains 

plug into a properly installed groun

-

ded socket.

• 

After reconnecting, the freshness 

cooler automatically starts the de

-

frosting process. After the defrosting 

process is complete, the freshness 

cooler automatically switches back 

to cooling mode.

•  After the defrosting process is com-

plete, check the temperature in the 

refrigerator compartment of the fresh 

food cooler.

• 

In the case of very heavy icing, it may 

be necessary to repeat this process 

up to three times.

Defrosting devices with bus connection

In the case of freshness coolers that are 

connected to a Wurm system via a bus 

connection, the manual defrosting pro

-

cess is also initiated via the store software 

or according to separate instructions 

directly on the thermostat controller.

Please note the information and ope-

rating instructions for the Wurm system 

used.

Summary of Contents for Usedom

Page 1: ...Operating Manual Refrigerated display cabinet Usedom Commercial refrigerated cabinet ...

Page 2: ...defrost running cooling is running fans are running 2 ...

Page 3: ...el load limit line impact protection light switch LED optional air intake grille thermostat controller button forward back program keys display icons temperature display substructure adjustable feet with thread M10 temperature display weighted air inlet and air outlet temperature 3 ...

Page 4: ... disconnect the refrigeration island from the power supply 12 Cleaning 13 Do not clean with 13 Defrost 13 Defrosting of devices without bus connection 13 Defrosting of devices with bus connection 13 Maintenance 14 Risk of injury 14 Risk of circuit 14 Decommissioning transport and storage 15 Productdetails and functionality 15 Climate class 15 Cooling unit 15 Housing and cooling storage 15 Temperat...

Page 5: ...pecific guidelines and laws abroad Keep this operating instruction for further use If you pass the cooler on to third parties be sure to include these opera ting instructions 5 Explantion of symbols The following symbols and signal words are used in this user manual on the freshness cooler or on the packaging This signal symbol word indicates a hazard with a high level of risk which if not avoided...

Page 6: ... surfa ces Caution danger of explosion Entering the surface prohibited Read the user manual Intended use The freshness cooler is a commercial refrigeration unit It is designed as sales furniture for packaged food in tempera ture class M1 in the self service area The freshness cooler is not suitable for use on board ships or aircrafts It must be ensured that the set and rea ched temperature inside ...

Page 7: ...e found on the type plate of the cooler and on the product data sheet which you can obtain from KMW customer service Only use the freshness cooler as descri bed in this user manual Any other use is considered improper and can lead to property damage or even personal injury The freshness cooler is not a child s toy The manufacturer assumes no liability for any injury loss or damage resulting from i...

Page 8: ...facturer Electric shock hazard Faulty electrical installation or excessive mains voltage can lead to electric shock Safety instructions for the authorized spe zialist Only connect the freshness cooler if the mains voltage and mains fre quency of the socket correspond to the information on the rating plate Only connect the cooler to an easily accessible socket so that you can quickly disconnect the...

Page 9: ...tments to the tempera ture controller to be carried out by authorized specialists To do this con tact KMW customer service Safety instructions for the authorized spe zialist Only parts that correspond to the original device data may be used for repairs This cooler contains electrical and mechanical parts that are essential to protect against sources of danger Do not operate the freshness cooler wi...

Page 10: ...commit to repair minor damage to the freshness ooler that does not impair any technical functions e g dents in the housing cau sed by shopping trolleys If there is damage to the refrigeration system or the electrics the KMW custo mer service must be informed immedia tely Otherwise there is a considerable risk of injury In case of improper handling or use the re is a risk of damaging the cooler and...

Page 11: ... cooler in a single or row installation a minimum distance of 50mm to all four boun dary surfaces such as walls other devices shelves etc must be main tained The installation location should not be exposed to excessive drafts or large heat sources This can impair the per formance of the freshness cooler In the case of block or row configura tions these must be ordered in ad vance to match Other in...

Page 12: ...ommends using a cable duct on the floor with sockets built into it or mounted on it to connect the cooler Electric circuit protection Before connecting the freshness cooler to an electrical circuit you must ensure that the corresponding electrical circuit is correctly secured Miniature circuit breakers LS switches for protection against overcurrent and residual current circuit breakers FI switches...

Page 13: ...start time of the automatic defrosting process is preset at the facto ry In exceptional cases it may be ne cessary to defrost the cooler manually e g due to a fault improper installation overloading after cleaning or due to other sources of interference The way you do this depends on whether your freshness cooler is connected to a wurm system or not Defrosting devices without a bus con nection Dis...

Page 14: ...r scrape off any existing lay er of ice or frost with pointed objects or tools This could damage the evapora tor Risk of injury In the event of improper handling or use there is a risk of injury from rotating fans and sharp edges When cleaning below the floor display the mains plug must be pulled out befo re cleaning Always use suitable protective gloves when cleaning the freshness cooler to avoid...

Page 15: ... pro per handling of the freshness cooler Climate class Cooling devices must always correspond to one of the climate classes 0 to 8 ac cording to the ISO 23953 2 standard The climate class specifies specifications for the environment in which the device is operated The cooler is designed as a device in climate class 3 for which a maximum ambient temperature of 25 C and a maximum relative humidity ...

Page 16: ... defrosts automatically at re gular intervals It is usually not necessary to defrost the cooler manually To do this observe the procedure in the chapters on cleaning and maintenance Temperature controller refrigeration controller With the help of the temperature cont roller the temperature in the goods area is regulated to an adjustable setpoint The temperature controller is set electro nically Al...

Page 17: ...dentally stored that were too warm Did you previously have a longer power outage Contact KMW customer service if the fault is not due to any of the causes listed here When contacting KMW Cus tomer Service always give the serial number of the cooler and the type of fault or a de scription of the malfunction In any case contact KMW customer service if loud noises and or strong vibrations occur on th...

Page 18: ...ions 1395x1100x980mm Internal dimensi ons 1270x700mm Glass display 1 1250x340mm Display area 1 62m Weight 215kg 18 Disposal Dispose of packaging Discard the packaging unmixed Give cardboard to the waste paper foils to the recyclables collection Dispose the freshness cooler Applicable in the European Union and other European countries with systems for separate collection of recyclables Old devices ...

Page 19: ...nized standards for Machinery Directive 2006 42 EG DIN EN 60335 1 2020 08 VDE 0700 1 2020 08 DIN EN 60335 289 2018 10 VDE 0700 89 2018 10 DIN EN 62233 2008 11 VDE 0700 366 2008 11 DIN EN 62233 Correction 1 2009 04 VDE 0700 366 correction 1 2009 04 DIN EN ISO 12100 2011 03 Applied harmonized standards for EMC directive 2014 30 EU DIN EN IEC 61000 3 2 2019 12 VDE 0838 2 2019 12 DIN EN 61000 3 3 2020...

Page 20: ...g GmbH is inadmissible and punishable This applies in particular to reproductions translations microfilms and the Feeding and processing in electronic systems Manufactured in 2022 by KMW Kühlmöbelwerk Limburg GmbH Limburger Strasse 80 D 65555 Limburg Article number 3042585 Imprint KMW Kühlmöbelwerk Limburg GmbH Gewerbegebiet Offheim Limburger Straße 80 D 65555 Limburg Tel 49 0 64 31 5 99 0 Fax 49 ...

Reviews: