background image

 

14 

                                                   

Fan chamber

  WPA-BOX-14                                      13.10.2016 

 

 

 

13.

 

Sample of the Declaration of Conformity 

 
 

 

 

Declaration of conformity EC No. …………….. 

 

Manufacturer (eventually the authorized representative / importer): 
name:  

KLIMAWENT  S.A.

 

address:  

81-571 Gdynia

,  Chwaszczyńska 194

  

 

A person, authorized for issuing the technical documentation: 
 
hereby declares that the appliance: 
name:   

Fan chamber

 

 
type/model: 

WPA-BOX-14

 

serial number:  ……………………………..  year of production:  ……………………….. 
 
meets the requirements of the subsequent European Directives:

 

 

 

2006/42/EC

 

Machinery Directive  

of the European Parliament and of the Council of May17

st

, 2006  on machinery  

– amending the 95/16/EC (recast)  /

Journal of Laws EC L157 of 09.06.2006, page 24

 

 

 

2014/35/EC Directive 

of the European Parliament and of the Council of February 26

st

, 2014  on the harmonisation 

of the laws  of the Member States,  relating to the making available on the market of electrical equipment designed  
for use within certain voltage limits.  /

Journal of Laws EC L96  of 29.03.2014

 
 

The appliance meets the requirements included in: 

 

2009/125/EC (ErP)

 

Directive 

of the European Parliament and of the Council  

of October 21

th

, 2009 establishing a framework for the setting of ecodesign requirements 

for energy-related products / 

Journal of Laws L 285 of 31.10.2009

 

 

 

 

327/2011

 (

EU

Guideline 

of March 30

th

, 2011 on implementing the 

2009/125/EC Directive

 

 

of the European Parliament and of the Council with regard to ecodesign requirements 
for fans driven by motors with an electric input power between 125W and 500 kW 
/

Journal of Laws L No. 90  of 06.04.2011

/

 

 
 

The device has been constructed and produced on the basis of following harmonized standards: 

 

PN-EN ISO-12100:2012 

 
 

 

“Safety of machinery.  Basic concepts, general principles  

 

 

 

for design.  Risk assessment and risk reduction”. 

 

 

 

 

 

PN-EN 60204-1:2010

 

 
 

 

“Safety of machinery.  – Electrical equipment of machines.  

 

 

 

Part 1:  General requirements”. 

 

 

 

 

 

PN-EN 60034-1:2011E 

 
 

 

“Rotating electrical machines – Part 1: Rating data  

 

 

 

and parameters”. 

 

 

 

 

 

PN-EN ISO 5802:2008E 

 
 

 

“Industrial Fans – Performance testing in situ of installing”. 

 

 

 

 

 

PN-EN ISO 13857:2010 

 

“Safety of machinery.  Safe distances to prevent hazard  

 

 

 

zones being reached by upper and lower limbs”. 

 

…………………………… 

…………………………… 

…………………………… 

place, date 

signature of authorised person 

name, surname, function 

 

 

of the signatory 

 

KLIMAWENT  S.A. 

District Court Gdańsk-Północ 

NIP:  958 159 21 35 

Supported Employment Enterprise 

in Gdańsk,  VII Wydział Gospodarczy  REGON:  220631262 

81-571 Gdynia, 

ul. Chwaszczyńska 194

 

of the National Register of Court 

Bank Account:  

Santander Bank Polska S.A. 

phone: +49 58 829 64 80 

KRS 0000308902  company stock 

56 1500 1025 1210  2007 8845 0000 

email:  

[email protected]

  13.779.200 zł paid in total 

 

www.klimawent.com.pl

   

 

 

 
 

 

Summary of Contents for WPA-BOX-14

Page 1: ...1 13 10 2016 Fan chamber WPA BOX 14 Use and Maintenance Manual Fan chamber WPA BOX 14...

Page 2: ...ations of Producer 4 4 Technical Data 4 5 Structure and Function 8 6 Assembly and Start up 10 7 Operational Use 12 8 Troubleshooting Guide 12 9 Maintenance 12 10 Occupational Health and Safety 13 11 T...

Page 3: ...ing to the making available on the market of electrical equipment designed for use within certain voltage limits Journal of Laws EC L96 of 29 03 2014 The appliance meets the requirements included in 2...

Page 4: ...tion with the air create explosive atmosphere F Do not use the device for conveying the air containing viscous impurities that could accumulate build up on the device surface especially on the impelle...

Page 5: ...5 13 10 2016 Fan chamber WPA BOX 14 Fig No 1 Dimensions of the fan chamber WPA BOX 14 Caution The dimension H is pertaining to holes spacing 10 used for anchorage the chamber...

Page 6: ...ensions of the fan chamber Type A mm B mm C mm Connection diameters Pitch diameters of the connections H mm J mm K mm D mm E mm F mm G mm WPA BOX 14 1641 1605 1666 400 400 430 430 766 M8 M8 Flow chart...

Page 7: ...kW see Table No 1 flow efficiency and pressure in the energy efficiency optimisation point see Table No 3 8 Rotations per minute see Table No 1 9 After the period of operational use follow steps acco...

Page 8: ...the floor and it is selec ted according to the weight of the fan stand frame set The fan inlet is equipped with a flange whereas the outlet is secured with a round fitting piece for attachment of the...

Page 9: ...degree Fan chamber with a silencer and air discharge at the silencer outlet Fan chamber with silencers at the inlet and outlet Photo No 1 Examples of application of additional silencers ADDITIONAL EQU...

Page 10: ...l power system has to be executed by User on one s own On the other hand it is important to select the right type and section of the supply cable and choose the appro priate short circuit and overload...

Page 11: ...h Q1 It 1 1 x In where In means rated current of the motor S1 isolating switch It is suggested to install it near the fan Purchase and installing depends on the Investor Connect the motor windings acc...

Page 12: ...tees its efficient function without continuous routing everyday technical supervision Nevertheless to obtain proper function of the device and to follow the safety rules manufacturer suggests executio...

Page 13: ...s this could cause the face injury of User 11 Transport and Storage The fan chamber is transported on a pallet The device has to be firmly fastened to the pallet to protect it from being overturned or...

Page 14: ...L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans dri...

Page 15: ...15 13 10 2016 Fan chamber WPA BOX 14 NOTES...

Page 16: ...amber WPA BOX 14 13 10 2016 Producer KLIMAWENT S A 81 571 Gdynia ul Chwaszczy ska 194 tel 058 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 814K49 WPA BOX 14 13 10...

Reviews:

Related manuals for WPA-BOX-14