stationary radial fan 

  

WPA

-

14

-

S

-

N

 

 

 

Before connection to the power supply,  make sure whether the parameters of the exis- 

ting electrical

 installation are corresponding

 the

 data on the nominal plate

.

  

In case of in

-

consistency, the connection cannot be executed

Connection to the electrical

 power system has to be executed 

by User on one’s own.

  

It is impor

tant to select the right type and section of the supply cable, and choose the appropriate short-
circuit- and overload protection, according to the local conditions. 

 

 

Connection to the 

power supply system ought 

to be carried out by an au-

 

thorized

 person with electrical qualifications,

  

and according to valid 

regulations and the

 

Connection Diagram in the Fig. No.4

 

Prior to the start-up, check the connection between the motor and 

the PE protective cable, and

  

the correctness of the electrical connections  (

the impeller rotation sense should be accor-

ding to the arrow on the housing

  

  

if this is not the case, change the phase connection 

sequence

). 

 

 

 

   

Approaching with loose clothes or putting the hand near the open inlet

 

of the running fan,

  

can cause hazard of accident and disability.

  

Absolutely, do not look  

into the working fan as this could cause the face injury of the operator

.

 

In case of any activities  carried out on the fan,

  

it is important

  

to disconnect the device  

from the power supply system

 

7.

 

Operational Use 

 

Construction of the

 device guarantees its reliable function

, without

 continuous technical routine 

supervision after the start-up

. If the place of

 operational use is changed, repeat the steps men-

mentioned in Section 6,  according to the installing

  

and adapting the ventilation system to the  

new conditions / another place of use.  In case when

  

any defective function of the unit occurs

   

(e.g. annoying noises or the outlook of the device)  follow steps as in Section 8. 

Caution

1. Insulation class  

I

 

2. Ingress protection  

IP54

 

3. Setting of the motor switch 

Q1

 

           

It 

= 1,1 x

 In 

 

     where  

In

 means rated current 

     of the motor. 
 
 

 

*

 

S1

 

– isolating switch (safety switch) 

    It is suggested to install it near the fan 

 

    Purchase and installing ought to be 
    carried out by the investor. 
 
Connect the motor windings 
according to the Connection  
diagram on the terminal box cover. 

 

Fig. No.4  

–  Connection Diagram of the fans type WPA-14-S-N

 

 

 

Summary of Contents for WPA-14-S-N

Page 1: ...1 04 06 2019 stationary radial fan WPA 14 S N Use and Maintenance Manual Stationary radial fan WPA 14 S N 801W15 WPA 14 S 3 N 04 06 2019 EN...

Page 2: ...WPA 14 S N stationary radial fans meets the requirements of the cur rent state of technology as well as the safety and health assurances included in 2006 42 EC Machinery Directive of the European Parl...

Page 3: ...cous impurities aggressive contamination or compounds creating hazard of explosion 3 Reservations of Producer A Manufacturer accepts no liability for any consequences following from the operational us...

Page 4: ...WPA 14 S 3 N 3000 3x400 15 54 100 91 23100 4000 182 1 Maximum temperature of the conveyed air is 60 C whereas maximum temperature within the work zone 40 C 2 Maximum dustiness of the conveyed air shou...

Page 5: ...the nominal data plate 7 Rated power consumption of the motor kW see Table No 1 flow efficiency and pressure in the energy efficiency optimization point see Table No 3 8 Rotations per minute see Tabl...

Page 6: ...n inlet is equipped with a flange whereas the fan outlet is ended with a round connec tion fitting piece to provide a safe fastening to the spiral seam duct rigid conduit or for flexible couplings For...

Page 7: ...es or putting the hand near the open inlet of the running fan can cause hazard of accident and disability Absolutely do not look into the working fan as this could cause the face injury of the operato...

Page 8: ...vibration measurement Before the maintenance necessarily disconnect the fan from the power supply system and wait until the impeller stops rotating Within the scope of inspection execute following act...

Page 9: ...well ventilated rooms 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The war ranty does not comprise mechanical damage and dysfunctions caus...

Page 10: ...roducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign r...

Page 11: ...11 04 06 2019 stationary radial fan WPA 14 S N NOTES...

Page 12: ...12 stationary radial fan WPA 14 S N 04 06 2019 NOTES...

Reviews: