4.

 

Technical Data 

Table No.1 

 

Type of the fan  Synchro- 

nous 

rotations 

Supply 

voltage 

Motor 

rate 

Ingress 

pro-

tection 

Acoustic 

pressure level 

[dB(A)] 

from distance

 

Maximum 

volume 

flow 

Maximum 

vacuum 

Weight 

 

[r.p.m.] 

[V] 

[kW] 

IP 

1m  

5m 

[m

3

/h] 

[Pa] 

[kg] 

WPA-14-S-3-N 

3000 

3x400 

15 

54 

100 

91 

23100 

4000 

182 

 

1. 

Maximum temperature of the conveyed air is +

60ºC

;

  

whereas maximum temperature within 

the work zone +4

0ºC. 

2. 

Maximum dustiness of the conveyed air should not exceed 0,3 g/m

3

 

Fig. No.1  

–  WPA-14-S-N  –  Structure, dimensions 

 
 

 

Table No.2  

–  Dimensions of the fan type WPA-14-S-N 

Type of the fan 

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[pcs]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

[mm]

 

WPA-14-S-N 

1000 1200  100  1100  760  400  400  430 

10  640  840  400  455  915 

Summary of Contents for WPA-14-S-N

Page 1: ...1 04 06 2019 stationary radial fan WPA 14 S N Use and Maintenance Manual Stationary radial fan WPA 14 S N 801W15 WPA 14 S 3 N 04 06 2019 EN...

Page 2: ...WPA 14 S N stationary radial fans meets the requirements of the cur rent state of technology as well as the safety and health assurances included in 2006 42 EC Machinery Directive of the European Parl...

Page 3: ...cous impurities aggressive contamination or compounds creating hazard of explosion 3 Reservations of Producer A Manufacturer accepts no liability for any consequences following from the operational us...

Page 4: ...WPA 14 S 3 N 3000 3x400 15 54 100 91 23100 4000 182 1 Maximum temperature of the conveyed air is 60 C whereas maximum temperature within the work zone 40 C 2 Maximum dustiness of the conveyed air shou...

Page 5: ...the nominal data plate 7 Rated power consumption of the motor kW see Table No 1 flow efficiency and pressure in the energy efficiency optimization point see Table No 3 8 Rotations per minute see Tabl...

Page 6: ...n inlet is equipped with a flange whereas the fan outlet is ended with a round connec tion fitting piece to provide a safe fastening to the spiral seam duct rigid conduit or for flexible couplings For...

Page 7: ...es or putting the hand near the open inlet of the running fan can cause hazard of accident and disability Absolutely do not look into the working fan as this could cause the face injury of the operato...

Page 8: ...vibration measurement Before the maintenance necessarily disconnect the fan from the power supply system and wait until the impeller stops rotating Within the scope of inspection execute following act...

Page 9: ...well ventilated rooms 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The war ranty does not comprise mechanical damage and dysfunctions caus...

Page 10: ...roducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign r...

Page 11: ...11 04 06 2019 stationary radial fan WPA 14 S N NOTES...

Page 12: ...12 stationary radial fan WPA 14 S N 04 06 2019 NOTES...

Reviews: