dust separator
WE-5,5/D
Fig. No.3
– WE-5,5/D – Maintenance
6.
Assembly and Start-up
WE-5,5/D dust separator is designed for use in a closed room (indoor application). It should
be placed stably on an even floor surface. Important is the free access of the cooling air cir-
culation and that there is enough place to replace the bag filter and the waste bag. It is re-
commended to install a silencer at the outlet, as this significantly reduces the noise level.
ZE-WE-5,5/D control unit ought to be installed in a place that is convenient for User. Addi-
tionally, it is important to provide 3x230V, 50Hz or 3x400V, 50Hz power supply, depending
on the supply versions. The control unit provides possibility of controlling the device function
from the switchgear or from the external closable contact. Additionally, a non-potential con-
tact is guided onto the X4 terminal strip (see Connection Diagrams). The non-potential con-
tact is closed during the work of the fan.
The device should be connected to the power supply system
by User on one’s own,
by selecting the appropriate sort and section of the supply cables and an appropriate
protection from the short-circuit- and overload effects
– according to the being valid
regulations and with reference to the local conditions.
Any activities pertaining to connection to the power supply system
have to be performed exclusively by an authorised person with testified qualifications
and in compliance with the being in force valid regulations
.
Prior to the device start-up examine subsequent aspects:
the voltage value of the supply installation,
connection correctness of the protective cable,
connection correctness of the electrical installation and selection of the protections,
mounting and tightness of the bag filter, waste bag and housing covers.