2
RADIAL ROOF FANS
SMART-N 31.05.2019
1.
Introductory Remarks
The purpose of the present Use and Maintenance Manual is to supply User with directions wi-
thin the range of application, installation,
start-up
and the operational use
of the
SMART-N radial
roof fans
.
Installing, start up and operational use are exclusively admissible after getting acquaint-
ted with the contents of the Use and Maintenance Manual
.
With regard to continuity of work carried on
improvement
of our
products, we reserve for oursel-
ves the revision possibility of the draft and technological changes improving
their functional features and safety.
The construction
of the
SMART-N radial roof fans
meets
the requirements
of the current state
of technology as well as the safety and health assurances included in:
2006/42/EC
Machinery Directive
of the European Parliament
and of the Council of
May 17
th
,
2006 on machinery
– amending the 95/16/EC (recast)
/
Journal of Laws EC L157 of 09.06.2006, page 24
/
2014/35/EC Directive
of the European Parliament and of the Council of February 26
th
, 2014
on the harmonisation of the laws of the
Member States relating to the making
available
on the
market of electrical equipment designed for
use within certain voltage limits. /
Journal of Laws EC
L96 of 29.03.2014
/
The appliance meets the requirements included in:
2009/125/EC (ErP)
Directive
of the European Parliament and of the Council of October 21
th
,
2009
establishing a framework
for the
setting of ecodesign requirements
for energy-related pro-
ducts /
Journal of Laws L 285 of 31.10.2009
/
327/2011
(
EU
)
Regulation
of March 30
th
, 2011 on implementing the
2009/125/EC Directive
of the European Parliament and of the Council
with regard to ecodesign requirements
for fans
driven by motors with an electric input power between 125W and 500 kW /
Journal of Laws L
No. 90 of 06.04.2011
/
The device has been constructed and produced on the basis of following harmonized standards:
●
EN ISO-12100:2012
–
“Safety of machinery. Basic concepts, general principles
for design. Risk assessment and risk reduction”
●
EN 60204-1:2018-12
–
“Safety of machinery – Electrical equipment of machines.
Part 1: General requirements”
●
EN 60034-1:2011
–
“Rotating electrical machines – Part 1: Rating data and
pa
rameters”
●
EN ISO 5802:2008/A1:2015-07
–
“Industrial Fans – Performance testing in situ of installing
●
EN ISO 13857:2010
–
“Safety
of
machinery
–
Safe distances
to
prevent hazard
zones being reached by upper and lower limbs”.
2.
Application
SMART-N radial roof fans are meant for general ventilation of rooms, in common- and indus-
trial buildings. Moreover, they can also be applied in the technological ventilation installations
(local
exhausts).
Due to their disposable pressure, they can be connected to a system of ven-
tilation ducts.
The fans are meant for forwarding the dry air of dustiness not exceeding 0
,3 g/m³ and
of maximum temperature 60
C, without viscous impurities, aggressive compounds or
substances creating explosion hazard.
3.
Reservations of Producer
A.
Manufacturer accepts no liability for any consequences following from the operational use
that is in contradiction to the purpose of application.
B.
It is unacceptable to install on
the device structure any additional elements not belonging to
its normal construction or accessory set.
C.
Do not introduce any structural changes or
modification of the appliance on one’s own.