RADIAL  ROOF  FANS

  SMART-N                                      31.05.2019 

   

 

In the Fig. No.2  are displayed dimensions and structure  of the fans SMART-N of rotational  
speed 3000 r.p.m. 

 

 

Fig. No.2  

–  SMART-N fans of 3000 r.p.m.  –  structure and dimensions 

 

Table No.11  

–  Dimensions of the fans type SMART-N of rotational speed 3000 r.p.m. 

  Type of the fan 

Ø

Ø

Ø

Quantity of holes 

Ø10 

  SMART-160/3000-N

 

590 

220 

540 

160 

194 

  SMART-200/3000-N

 

590 

220 

540 

200 

224 

  SMART-250/3000-N

 

590 

220 

540 

250 

274 

  SMART-315/3000-N

 

590 

220 

540 

315 

344 

 

6.

 

Assembly and Start-up 

To mount the fan on a roof (of the industrial building) it is important to install it on a pedestal with  
a suitable roof base. 

It is recommended to apply the 

TPD-N or TPDC-N sound absorbing

 roof bases  

(

delivery on 

separate order 

 below, in Fig. No.4 and No.5 are given their dimensions

).

 

The application roof bases itself, reduces the noise coming into the process room by 12 up to 18 
dB(A). 
In 

order to reduce more the noise level,

 install a silencer beneath the roof base, suspending inside  

the room. 

Before lifting and installing the fan

 

(

onto the 

roof base

)

 it is important to use special lifting  

eye bolts, screwed up to the disk 

underneath the motor

 

– before doing this, take off the fan 

hood.  Do not use the motor eye-bolt handle for transporting the whole fan

 

Summary of Contents for SMART-160/3000-N

Page 1: ...812W70 SMART 400 750 N 31 05 2019 EN 812W61 SMART 200 1000 N 31 05 2019 EN 812W71 SMART 400 1000 N 31 05 2019 EN 812W62 SMART 200 1500 N 31 05 2019 EN 812W72 SMART 400 1500 N 31 05 2019 EN 812W63 SMA...

Page 2: ...of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power...

Page 3: ...ional use 4 Technical Data Table No 1 Type of the fan Synchronous rotations Supply voltage Motor rate Maximum volume flow Maximum fan pressure Weight r p m V Hz kW m h Pa kg SMART 160 3000 N 3000 3 x...

Page 4: ...2019 Flow charts Table No 2 SMART 160 3000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 79 69 62 59 71 Table No 3 SMART 200 1000 N Acoustic pressure level dB A outlet inlet 1 m 5...

Page 5: ...sure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 79 69 62 59 71 Table No 4 SMART 250 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 65 56 48 44 53 SMART 250 1500 N Acoustic p...

Page 6: ...oustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 68 59 51 48 59 SMART 315 1500 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 80 70 63 60 70 SMART 315 3000 N Acoustic p...

Page 7: ...ustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 63 55 46 43 53 SMART 400 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 73 62 56 52 62 SMART 400 1500 N Acoustic pr...

Page 8: ...MART N 31 05 2019 Table No 7 SMART 500 750 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 69 59 52 49 61 SMART 500 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m...

Page 9: ...ROOF FANS SMART N Table No 8 SMART 630 750 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 77 67 60 56 70 SMART 630 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m...

Page 10: ...a motor with a radial impeller Impeller is statically and dynamically balanced according to ISO 14694 2003 AMD1 2010 gaining the G 2 5 class Lower skeletons of the 3000 r p m synchronous rotation fans...

Page 11: ...fans of 3000 r p m Fig No 1 Fans of SMART N types structure and dimensions Table No 10 Dimensions of the fans type SMART N except for fans of rotational speed 3000 r p m Type of the fan A B C D E Qua...

Page 12: ...on a roof of the industrial building it is important to install it on a pedestal with a suitable roof base It is recommended to apply the TPD N or TPDC N sound absorbing roof bases delivery on separat...

Page 13: ...and positioned at the place of operation Connection flange Fig No 3 Connection flange of the fan dimensions Table No 12 Dimensions of the connection flanges Type of the fan Connection flange A mm B mm...

Page 14: ...C 160 N 160 430 630 625 SMART 200 N TPDC 200 N 200 430 630 625 SMART 250 N TPDC 250 N 250 530 730 950 SMART 315 N TPDC 315 N 315 530 730 950 SMART 400 N TPDC 400 N 400 790 990 1200 SMART 500 N TPDC 50...

Page 15: ...the fan even for a check before the hood is reinstalled CAUTION 1 Insulation class I 2 Ingress protection IP54 3 Setting of the motor protective switch Q1 It 1 1 x In where In means rated current o th...

Page 16: ...egular periods of time i e once a year During the check take into account the function of the fan as well as its technical state All the activities connected with technical revisions on the fan have t...

Page 17: ...t be neither thrown nor knocked down Do not put any additional load on the device It is inadmissible to put one device on top of another no stacking During the transport protect them from atmospheric...

Page 18: ...s Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign require...

Page 19: ...19 31 05 2019 RADIAL ROOF FANS SMART N NOTES...

Page 20: ...20 RADIAL ROOF FANS SMART N 31 05 2019 NOTES...

Reviews: