Klimawent ERGO-KOS-AL Use And Maintenance Manual Download Page 10

                                   10 

                                                     

extraction rail

  ERGO-KOS-AL                              

 

       

30.01.2019

 

   

 

Table No.3

 

Type of the fan 

 

 

 

 

Synchronous 

rotations 

 

 

[r.p.m.] 

Supply 

voltage 

 

 

[V] 

Motor 

rate 

 

 

[kW] 

Ingress 

protection 

 

 

IP 

Acoustic 

pressure level 

[dB(A)]   

from distance 

Maximum 

volume flow 

 

 

[m

3

/h] 

Maximum 

vacuum

 

 

 

[Pa] 

Weight 

 

 

 

[kg] 

1m  

5m 

WPA-5-D-1-N 

3000 

230 

0,37 

54 

73/67*  59/53* 

1900 

1250 

23 

WPA-5-D-3-N 

3 x 400 

WPA-6-D-1-N 

3000 

230 

0,75 

54 

78/75*  64/61* 

2500 

1700 

28  

WPA-6-D-3-N 

3 x 400 

WPA-7-D-1-N 

3000 

230 

1,1 

54 

81/74*  67/60* 

3100 

1800 

30 

WPA-7-D-3-N 

3 x 400 

WPA-8-D-3-N 

3000 

3 x 400 

1,5 

54 

82/78*  68/64* 

3900 

2050 

36  

WPA-9-D-3-N 

3000 

3 x 400 

2,2 

54 

86/82*  72/68* 

4500 

2400 

45  

WPA-10-D-3-N 

3000 

3 x 400 

3,0 

54 

87/81*  73/67* 

6200 

2450 

58  

WPA-11-D-3-N 

3000 

3 x 400 

5,5 

54 

91/88*  77/74* 

8050 

2950 

77  

WPA-13-D-3-N 

3000 

3 x 400 

7,5 

54 

95/90*  81/76* 

10800 

3300 

98  

 
Prior to operational use switch on the extraction fan and make sure that the installation is 
functioning properly. 
 

7.

 

Operational Use 

Low displacement resistance of the suction trolley  and easy manoeuvring with the extraction  
arm provide a convenient use  of the whole extraction system.  By means of the shut-off dam- 
per lever,  adjust the volume flow of the extracted air,   in a way  that efficiently eliminates the  
fume and dustiness, not causing excessive draft. 
During the operational use, the position of the extraction arm  and of the shut-off lever can be 
changed several times adapting the system to the current needs of User. 
Having completed the work close the shut-off damper (in the suction hood),  as this will impro- 
ve the suction capacity in the second extraction arm. 
One suction duct provides operational space for simultaneous function of two extraction arms. 
Adjustment of the brakes (in the arm joints), ought to be performed according to the individual 
instructions of the subsequent extraction arms. 
 

8.

 

Troubleshooting Guide 

Table No.4 

 

Problem 

Possible reason 

Remedial measure 

1. 

The extraction arm is falling.  Improperly adjusted frictional  

Increase the tension upon frictio- 

 

falling 

brake in the joint 

nal disks of the brake in the joint 

 

 

 

by tightening the adjustment nuts 

 

 

 

 

2. 

Drop in the air suction rate 

Improper impeller rotation sense  Change the phase connection  

 

along with the increased  

of the extraction fan 

sequence 

 

noise level of the extraction  The mesh holes of the inlet net   Clean them using a wire brush 

 

installation and arm 

are clogged 

 

 

Suddenly occurring vibra- 

Foreign matter / object got stuck  Disconnect the motor and  

 

tions of the fan 

within the impeller 

remove the object 

 

 

Impeller failure 

Replace the impeller for a new 

 

 

 

 

 
 

 

Summary of Contents for ERGO-KOS-AL

Page 1: ...cation 2 3 Reservations of Producer 2 4 Technical Data 2 5 Structure and Function 4 6 Assembly and Start up 4 7 Operational Use 10 8 Troubleshooting Guide 10 9 Maintenance 11 10 Occupational Health an...

Page 2: ...pts general principles for design Risk assessment and risk reduction 2 Application ERGO KOS AL is designed for extraction of welding fumes at mobile workplaces for linear wel ding of elements of lengt...

Page 3: ...n Sort of the connection Type Part No Diameter Remarks for axial connection KPC 804K20 160 To connect the suction duct to the extraction installation Duct hanger Sort of the hanger Type Part No Remark...

Page 4: ...elding the operator displaces the ERGO extraction arm with the trolley along the suc tion duct The suction hood ought to be adjusted at a distance at least ca 30 cm from the wel ding point Fig No 1 ER...

Page 5: ...tion duct Slide the OP ERGO L trolley into the KOS AL suction duct in such a way that the trolley rollers are displacing on the side guide rails of the duct profile two straps of the rubber apron shou...

Page 6: ...uction side of the fan connecting the self tightening duct with the fan c roof fan Extraction system with a fan for indoor installing a assembly of the KOS AL self tightening suction duct and trolley...

Page 7: ...7 30 01 2019 extraction rail ERGO KOS AL Fig No 5 Fig No 6...

Page 8: ...type T before the fan inlet the silencer length ought to be not less than 500 mm to connect the inlet and outlet of the fan with the installations by means with a flexible joint Flexible joints do no...

Page 9: ...A 6 E 1 N 3000 230 0 75 54 83 75 69 61 2500 1700 21 WPA 6 E 3 N 3000 3 x 400 0 75 54 83 75 69 61 2500 1700 WPA 7 E 1 N 3000 230 1 1 54 86 74 72 60 3100 1800 23 WPA 7 E 3 N 3000 3 x 400 1 1 54 86 74 72...

Page 10: ...fficiently eliminates the fume and dustiness not causing excessive draft During the operational use the position of the extraction arm and of the shut off lever can be changed several times adapting t...

Page 11: ...evere hazard to personnel people in the vicinity Start up and maintenance are exclusively possible after getting acquainted with the contents of the present Use and Maintenance Manual For the safety r...

Page 12: ...ion and with the present Use and Maintenance Manual mechanical damages and malfunctions caused by User changes modifications introduced by User on one s own malfunction resulting from the normal opera...

Page 13: ...13 30 01 2019 extraction rail ERGO KOS AL...

Page 14: ...030 335 160 Fig No 10 ERGO LUX L 2 ERGO LUX L 3 extraction arms Type L m A mm B mm C mm D mm E mm nxF mm G mm ERGO FLEX LUX 2 2 0 930 435 355 160 194 6x 6 5 295 ERGO FLEX LUX 3 3 0 1510 846 355 160 19...

Page 15: ...Parliament and of the Council of May 17th 2006 on machinery amen ding the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The appliance meets following harmonized standard EN ISO 12100 2...

Page 16: ...16 extraction rail ERGO KOS AL 30 01 2019 NOTES...

Reviews: