Klimawent ERGO-FLEX LUX Use And Maintenance Manual Download Page 8

                                   8 

                                                       

Extraction Arm

  ERGO-FLEX LUX                    

 

       10.01.2019 

   

 

 
START-UP 

● 

Prior to beginning of the work, check if the extraction fan is functioning or make sure if the 
discharge ductwork is working properly. 

 

 

● 

Adjust the hood into suitable position:  not more than 30 cm from the welding arc,

  

and not  

less than 20 cm 

– as the welding chippings (spatters) could damage the hood

  

and, on the  

other hand,  the hood suction could interrupt the protection gas shield (CO

2

, argon).   

Simultaneously, the hood should capture the fume effectively, 

whereby

, the extraction arm 

shall not cause barrier to User. 

 

 

● 

By means of  the shut-off damper lever  adjust the intake air volume  to eliminate the fume  
and/or dustiness most efficiently. 

 

 

● 

During the operational use, the position of the hood and the damper lever can be changed 
many times,  so User can adjust them best to the current needs. 

 

 

● 

After the work is completed 

– the extraction

 arm can be left in the 

ultimate

 

used position (ope-

rational state), or if it causes obstacle 

– set the arm into the home position. 

 

 

● 

Switch off the extraction fan; in case where the extraction arm works

 in a ventilation system 

 

– close the shut-off damper. 

 

 

 

7.  Operational Use 

In general,

  

the device construction guarantees a safe and reliable function without continuous  

routine servicing and special handling.   
If necessary

, undertake the

 adjustment of the frictional joints. First take off 

the hose clamp, and

   

and sleeve the hose off until the joint is accessible.   
The bolts and nuts in the joints are fine-threaded (1 mm pitch). The adjustment of the frictional  

brakes is carried out by increasing or reducing the

 

tension of the nuts upon the frictional

 elements.   

 

In general,

 the brake adjustment in the following joints ought to be executed in such a way that 

provides stability and self-supporting features of the extraction arm (which is important to keep  
the stable arm position).  Whereas, 

on

 the other hand,

 this

 cannot cause any excessive friction 

resistance while User is changing the arm position. 
Having completed the adjustment,  tighten up the counter-nuts.   
 

 

Summary of Contents for ERGO-FLEX LUX

Page 1: ...1 10 01 2019 Extraction Arm ERGO FLEX LUX Use and Maintenance Manual Extraction Arms ERGO FLEX LUX ...

Page 2: ... Reservations of Producer 3 4 Technical Data 4 5 Structure and Function 7 6 Assembly and Start up 7 7 Operational Use 8 8 Troubleshooting Guide 9 9 Maintenance 9 10 Occupational Health and Safety 9 11 Transport and Storage 10 12 Terms of warranty 10 13 Sample of the Declaration of Conformity 13 ...

Page 3: ...tion 2 Application ERGO FLEX LUX Extraction Arms have been developed for capturing the welding dust parti cles and welding gas as well as other fine dust particles directly at the emission source in order to avoid the contamination expanding within the process room hall and protect the people in the vicinity from inhaling the contamination The extraction arms are manufactured in hanging and standi...

Page 4: ...m mm mm mm mm mm mm kg ERGO FLEX LUX 2 Ø160 2 930 435 355 Ø194 6 x Ø6 5 Ø295 8 5 ERGO FLEX LUX 3 3 1510 846 9 6 ERGO FLEX LUX 4 4 1890 1435 10 2 ERGO FLEX LUX 2 R 2 1230 435 8 4 ERGO FLEX LUX 3 R 3 1810 846 9 1 ERGO FLEX LUX 4 R 4 2190 1435 9 8 Fig No 1 Dimensions of the extraction arms type ERGO FLEX LUX ...

Page 5: ...GO FLEX LUX Table No 2 Hood Type G Z T H Application Weight mm mm mm mm kg LST Ø295 Ø365 Ø170 190 ERGO FLEX LUX 2 ERGO FLEX LUX 3 ERGO FLEX LUX 4 ERGO FLEX LUX 2 R ERGO FLEX LUX 3 R ERGO FLEX LUX 4 R 0 42 Flow chart ERGO FLEX LUX 2 ...

Page 6: ...6 Extraction Arm ERGO FLEX LUX 10 01 2019 Flow chart ERGO FLEX LUX 3 Flow chart ERGO FLEX LUX 4 ...

Page 7: ...ng provide the comfort of easy manoeuvring with the extraction arm 6 Assembly and Start up ERGO FLEX LUX extraction arms along with the hoods are delivered in separate cardboard packages The suction hood has to be fastened according to the Assembly instruction of the ERGO FLEX LUX extraction arms on page 11 Diameters and the hole pattern for the mounting bolts are identical in the wall bracket and...

Page 8: ...sed position ope rational state or if it causes obstacle set the arm into the home position Switch off the extraction fan in case where the extraction arm works in a ventilation system close the shut off damper 7 Operational Use In general the device construction guarantees a safe and reliable function without continuous routine servicing and special handling If necessary undertake the adjustment ...

Page 9: ... most efficient capture In application for wel ding dusts sprinkle additionally them with the anti gluing anti spattering fluid against chip pings In case when the extraction arm is losing its self supporting properties undertake the ad justment of its frictional brakes Lubricate the swivel every 3 months using solid grease lubrication nipple is located on the swivel flange After 1 operational yea...

Page 10: ...he purchased device is indicated in the Card of Warranty The warranty does not comprise device failures caused during use which was in contradiction with the purpose of operatio nal use and with the present Use and Maintenance Manual mechanical electrical damages and malfunctions caused by User modifications and changes on the appliance undertaken by User on one s own inefficiency or malfunctions ...

Page 11: ...frictional joint at the swivel in such a way that the extraction arm is easy to ma noeuvre and is stable in keeping the requested arm position 5 Sleeve the hose onto the swivel and fold up the hose edge inwards and subsequently se cure it with a hose clamp 6 Adjust the middle joint similarly as in Clause 4 7 Install the hood at the extraction arm according to the Detail A Adjust the frictional joi...

Page 12: ...ping the requested arm position 4 Sleeve the hose onto the swivel and fold up the hose edge inwards and subsequently se cure it with a hose clamp 5 Adjust the middle joint similarly as in Clause 3 6 Install the hood at the extraction arm according to the Detail A Adjust the frictional joint of the hood in such a way that it is easy to manoeuvre with the hood and it is keeping the requested operati...

Page 13: ... May 2006 on machinery amending the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The device has been constructed and produced on the basis of following harmonized standards PN EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction place date signature of authorised person name surname function of the signatory KLIMAWEN...

Page 14: ...14 Extraction Arm ERGO FLEX LUX 10 01 2019 NOTES ...

Page 15: ...15 10 01 2019 Extraction Arm ERGO FLEX LUX NOTES ...

Page 16: ...629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 810R42 ERGO FLEX LUX 2 10 01 2019 EN 810R43 ERGO FLEX LUX 3 10 01 2019 EN 810R44 ERGO FLEX LUX 4 10 01 2019 EN 810R45 ERGO FLEX LUX 2 R 10 01 2019 EN 810R46 ERGO FLEX LUX 3 R 10 01 2019 EN 810R47 ERGO FLEX LUX 4 R 10 01 2019 EN ...

Reviews: