Klimawent ALAN-U/E-10-HD-N Use And Maintenance Manual Download Page 9

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

24.05.2019

 

Reel Exhaust Extractor

 ALAN-U/E-HD-N

 

9 z 12 

 

Maintenance  Manual.   

Connection  to  the  power  system  ought  to  be  executed  by  a  person  of  electrical 

qualifications and in compliance with the valid safety regulations

The fan motor has to be connected to the electrical wiring system 

– according to the present regulations within 

the range of personnel protection from electric shock and short-circuit- overload effects. 

Necessarily check the impeller rotation sense, it has to be with reference to the arrow on the fan housing 

(

this refers the three-phase motors only

).

 

Prior to installing the Reel Exhaust Extractor check the load carrying capacity of the building structure where the 
device shall be mounted.  Unsure mounting could result in an uncontrolled device detachment from the wall or 
ceiling and cause risk to User or personnel / people in the vicinity. 

Any activities related to electricity ought to 

be carried out after the fan motor is disconnected from the power system

For  safety  reasons,  while  the  hose  is  recoiled  onto  the  reel,  User  should  hold  the  nozzle  by  hand  until  it  is 
completely wound on the reel.  Therefore,  the hose is winding evenly and not getting jammed.  
 
 

 

TRANSPORT   AND  STORAGE 

The device ought to be stored in a dry and well ventilated room.  It should be placed in horizontal position, with 
the winding reel upwards, on 2 wooden beams 60x60x500 mm.  It is not acceptable to store one reel extractor on 
top of another (stacking).  For the time of transport it has to be placed in a way described above, in foil and placed 
in a cardboard package as well as protected from an uncontrolled displacement and overturn. During transporting 
and storage, the accessories of the Reel Exhaust Extractor (e.g. hose assembly) ought to be in foil and placed in 
cardboard package. 
 

 

TERMS  OF  WARRANTY 

The period  of  warranty   for  the  purchased device  

is

 indicated in the 

Card 

of 

Warranty

. The warranty does 

not comprise: 
● 

mechanical damage and malfunctions caused by User, 

● 

device failures  caused during the use  which is in contradiction with the purpose of application and with the 
present Use and Maintenance Manual, 

● 

malfunctions resulting from the improper transport, storage or incorrect maintenance. 

Infringement of the  Section 3 “Reservations of Producer”  of the  present  Use  and  Maintenance Manual  and, 
especially modifications  undertaken by User on one’s own or use in contradiction with the purpose of application  
–  shall result in the loss of warranty validity. 

 

 

Summary of Contents for ALAN-U/E-10-HD-N

Page 1: ...FUNCTION 4 ASSEMBLY AND STARTUP 4 OPERATIONAL USE 7 TROUBLESHOOTING GUIDE 8 MAINTENANCE 8 OCCUPATIONAL HEALTH AND SAFETY 8 TRANSPORT AND STORAGE 9 TERMS OF WARRANTY 9 DECLARATION OF CONFORMITY 10 24 0...

Page 2: ...the optimum air extraction and simple use they provide a dis charge of the whole exhaust volume outside the premises The extractor can be installed under the ceiling or to the walls columns by means o...

Page 3: ...N reel extractor standard equipment Type of the hose assembly Hose diameter Weight Hose length Recomme nded volume flow Flow resistances1 Thermal resistance Cooperating fans mm kg m m h Pa C ZW 10 200...

Page 4: ...dial fan type FA installed directly to the hose reel delivery on separate order The outlet of the extractor or of the FA type fan ought to be connected with a rigid ventilation conduit to discharge th...

Page 5: ...side the reel screw up the reducer to the reducer body with 2 screws Fig No 3 Hose assembly installing 3 Put sleeve on the hose onto the nozzle and secure it with a hose clamp protected with a rubber...

Page 6: ...have diameter 160 or 200 mm To prepare the Reel Exhaust Extractor for operational use connect the fan motor and the ZE ALAN U E to the power supply system according to the enclosed Connection Diagram...

Page 7: ...omplete phase work and start up blocking Depending on the fan size we apply adequate control unit Table No 5 Specification of control units ZE ALAN U E Type of the control unit Supply voltage Motor ra...

Page 8: ...ficant drop in Solid element foreign object being Localise the obstacle object and remo the intake air volume obstacle barrier for the flow got ve it stack in the suction nozzle or in the exhaust hose...

Page 9: ...tely wound on the reel Therefore the hose is winding evenly and not getting jammed TRANSPORT AND STORAGE The device ought to be stored in a dry and well ventilated room It should be placed in horizont...

Page 10: ...s 2006 42 EC Directive of the European Parliament and of the Council of the 17 May 2006 on machinery amending the 95 16 EC Directive recast Official Journal EC L157 of the 09 06 2006 page 24 2014 35 E...

Page 11: ...Klimawent the warranty of highest quality at attractive price 24 05 2019 Reel Exhaust Extractor ALAN U E HD N 11 z 12 NOTES...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 12 Reel Exhaust Extractor ALAN U E HD N 24 05 2019 NOTES...

Reviews: