Klimawent ALAN-U/E-10-HD-N Use And Maintenance Manual Download Page 2

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

2 z 12 

Reel Exhaust Extractor

 ALAN-U/E-HD-N

 

24.05.2019 

 

 

INTRODUCTION 

The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of 
application, assembly, start-up and operational use of the 

ALAN-U/E-HD-N

 Reel Exhaust Extractor. 

 

Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction. 

 

With regard to continuity of work carried on improvement of our products, we reserve for 
ourselves  the  revision  possibility  of  the  draft  and  technological  changes  improving  their 
functional features and safety.

 

Construction of 

ALAN-U/E-HD-N

 meets the requirements of the current state of technology as well as the safety 

and health assurances included in: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 

2014/35/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the making available on the market of electrical equipment 
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014; 

Is in accordance with the subsequent harmonised standards: 

EN ISO-12100:2012

  

   

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

EN 60204-1:2018-12   

Safety of machinery 

– Electrical equipment of machines  – Part 1:  General requirements 

 

 

PURPOSE 

ALAN-U/E-HD-N

 Reel Exhaust Extractors with an electrical drive are designed for effective removal of noxious 

and hazardous chemical compounds emitted in exhaust gases of vehicles during diagnostics, adjustment, and 
engine  tests  and  similar.  They  are  used  in  bus  depots,  garages  and  service  stations  for  trucks,  building  con-
struction vehicles, special vehicles. Along with the optimum air extraction and simple use 

– they provide a dis-

charge of the whole exhaust volume outside the premises. 
The extractor can be installed under the ceiling or to the walls / columns by means of wall brackets. The system 
works with following fans manufactured by KLIMAWENT S.A.: 

– 

built-on fans 

FA

 

– installed directly at the exhaust reel, 

– 

flange-type fans 

WPA-E-N

 

– installed independently on a separate bracket, 

– 

roof fans 

WPA-D-N

 

 

RESERVATIONS  OF  MANUFACTURER 

 

Manufacturer  accepts  no  liability  for  any  consequences  following  from  the  operational  use  that  is  in 
contradiction to the purpose of application. 

 

Operational  use  with cooperation  with  an inefficiently functioning  extraction fan, as this  would result  in 
overheating and damage of the exhaust hose. 

 

Protect the exhaust hose  from mechanical damage  and  pollution  with oils and solid lubricating grease. 

 

Maintenance and any repair can be executed exclusively by an authorised person. 

 

During the use, the vehicle engine  is allowed to work at maximum rotations for not longer time 
than 60 seconds

 

During hose winding

 

– observe that the hose is distributing on the reel evenly, regularly to avoid clenching. 

 

Prior to installing 

– check the load carrying capacity of the ceiling / wall, in a place where the unit shall be 

installed;  unsure setting of mounting bolts could result in uncontrolled device detachment, its damage 
and risk to the operator / people in the vicinity. 

 

Installing of any additional elements  that are not belonging  to the normal device structure (or accessory 
set) is not acceptable. 

 

Do not introduce any structural or constructional modifications on the device on 

one’s own. 

 

Manufacturer is not responsible for body lacerations, injuries, wounds 

– experienced by operator due to 

careless use or negligence. 

 

 

TECHNICAL  DATA 

Table No.1 

Extractor type 

Equipped with a 
shut-off damper 

Maximum 

torque 

Maximum length of the 

exhaust hose 

Diameter of the 

exhaust hose 

Weight 

 

 

[Nm] 

[m] 

[mm] 

[kg] 

ALAN-U/E-10-HD-N 

no 

80 

10 

200 

44,5 

ALAN-U/E-15-HD-N 

no 

100 

15 

200 

68 

ALAN-U/E-22-HD-N 

no 

120 

22 

200 

95 

CAUTION:

  

1

upon selection of the extractor size 

– contact KLIMAWENT S.A. 

2

weight of the extractor is specified without the installed hose 

 

 

Summary of Contents for ALAN-U/E-10-HD-N

Page 1: ...FUNCTION 4 ASSEMBLY AND STARTUP 4 OPERATIONAL USE 7 TROUBLESHOOTING GUIDE 8 MAINTENANCE 8 OCCUPATIONAL HEALTH AND SAFETY 8 TRANSPORT AND STORAGE 9 TERMS OF WARRANTY 9 DECLARATION OF CONFORMITY 10 24 0...

Page 2: ...the optimum air extraction and simple use they provide a dis charge of the whole exhaust volume outside the premises The extractor can be installed under the ceiling or to the walls columns by means o...

Page 3: ...N reel extractor standard equipment Type of the hose assembly Hose diameter Weight Hose length Recomme nded volume flow Flow resistances1 Thermal resistance Cooperating fans mm kg m m h Pa C ZW 10 200...

Page 4: ...dial fan type FA installed directly to the hose reel delivery on separate order The outlet of the extractor or of the FA type fan ought to be connected with a rigid ventilation conduit to discharge th...

Page 5: ...side the reel screw up the reducer to the reducer body with 2 screws Fig No 3 Hose assembly installing 3 Put sleeve on the hose onto the nozzle and secure it with a hose clamp protected with a rubber...

Page 6: ...have diameter 160 or 200 mm To prepare the Reel Exhaust Extractor for operational use connect the fan motor and the ZE ALAN U E to the power supply system according to the enclosed Connection Diagram...

Page 7: ...omplete phase work and start up blocking Depending on the fan size we apply adequate control unit Table No 5 Specification of control units ZE ALAN U E Type of the control unit Supply voltage Motor ra...

Page 8: ...ficant drop in Solid element foreign object being Localise the obstacle object and remo the intake air volume obstacle barrier for the flow got ve it stack in the suction nozzle or in the exhaust hose...

Page 9: ...tely wound on the reel Therefore the hose is winding evenly and not getting jammed TRANSPORT AND STORAGE The device ought to be stored in a dry and well ventilated room It should be placed in horizont...

Page 10: ...s 2006 42 EC Directive of the European Parliament and of the Council of the 17 May 2006 on machinery amending the 95 16 EC Directive recast Official Journal EC L157 of the 09 06 2006 page 24 2014 35 E...

Page 11: ...Klimawent the warranty of highest quality at attractive price 24 05 2019 Reel Exhaust Extractor ALAN U E HD N 11 z 12 NOTES...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 12 Reel Exhaust Extractor ALAN U E HD N 24 05 2019 NOTES...

Reviews: