background image

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

2 z 12 

Reel Exhaust Extractor

 ALAN-U/C-N

 

23.05.2019 

 

 

INTRODUCTION 

The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of 
application, assembly, start-up and operational use of the 

ALAN-U/C-N

 Reel Exhaust Extractor. 

 

Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction. 

 

With regard to continuity of work carried on improvement of our products, we reserve for 
ourselves  the  revision  possibility  of  the  draft  and  technological  changes  improving  their 
functional features and safety.

 

Construction of 

ALAN-U/C-N

 meets the requirements of the current state of technology as well as the safety and 

health assurances included in: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 
 
Additionally, it is in accordance with the subsequent harmonised standards: 

EN ISO-12100:2012

  

   

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

 

 

PURPOSE 

ALAN-U/C-N

  Reel  Exhaust  Extractors  with  a  spring  drive  are  designed  for  effective  removal  of  noxious  and 

hazardous chemical compounds emitted in exhaust gases of vehicles during diagnostics, adjustment, and engine 
tests and similar. They eliminate health hazards and risk of life of the operating personnel, provide clean air at the 
workplace,  thereby providing more safety and comfort.  They are used in bus depots, garages and car service 
stations.   
Simple use, ergonomic and economic solution as well as high capture efficiency 

– are their basic advantages. 

The extractor can be installed on a wall, under the ceiling and this provides efficient organisation at the workplace,  
(i.e. not being obstacle for a car lift or for high vehicles). 
The appliance works with following fans manufactured by KLIMAWENT S.A.: 

– 

built-on fans 

FA

 

– installed directly at the exhaust reel, 

– 

flange-type fans 

WPA-E-N

 

– installed independently on a separate bracket, 

– 

roof fans 

WPA-D-N

 

 

RESERVATIONS  OF  MANUFACTURER 

 

Manufacturer  accepts  no  liability  for  any  consequences  following  from  the  operational  use  that  is  in 
contradiction to the purpose of application. 

 

Operational  use  with  cooperation  with  an inefficiently functioning  extraction fan, as this  would result  in 
overheating and damage of the exhaust hose. 

 

Protect the exhaust hose  from mechanical damage  and  pollution  with oils and solid lubricating grease. 

 

Maintenance and any repair can be executed exclusively by an authorised person. 

 

During  the  use,  the  vehicle  engine  can  work  at  maximum  rotations  for  not  longer  time  than  60 
seconds

 

During hose winding

 

– observe that the hose is distributing on the reel evenly, regularly to avoid clenching. 

 

Prior to installing 

– check the load carrying capacity of the ceiling / wall, in a place where the unit shall be 

installed;  unsure setting of mounting bolts could result in uncontrolled device detachment, its damage 
and risk to the operator / people in the vicinity. 

 

Installing of any additional elements  that are not belonging  to the normal device structure (or accessory 
set) is not acceptable. 

 

Do not introduce any structural or constructional modifications on the device on 

one’s own. 

 

Manufacturer is not responsible for body lacerations, injuries, wounds 

– experienced by operator due to 

careless use or negligence. 

 

 

TECHNICAL  DATA 

 Table No.1 

Extractor type 

Equipped with a 
shut-off damper 

Maximum 

torque 

Maximum length of the 

exhaust hose 

Diameter of the 

exhaust hose 

Weight 

 

 

[Nm] 

[m] 

[mm] 

[kg] 

ALAN-U/C-8-N 

no 

50 

100 

125 

150 

44,5 

ALAN/P-U/C-8-N 

yes 

ALAN-U/C-12-N 

no 

12 

46,5 

ALAN/P-U/C-12-N 

yes 

CAUTION:

  

1

upon selection of the extractor size 

– contact KLIMAWENT S.A. 

2

weight of the extractor is specified without the installed hose 

 

 

Summary of Contents for ALAN-U/C-12-N

Page 1: ...ION 4 ASSEMBLY AND STARTUP 5 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 9 MAINTENANCE 9 OCCUPATIONAL HEALTH AND SAFETY 9 TRANSPORT AND STORAGE 10 TERMS OF WARRANTY 10 DECLARATION OF CONFORMITY 11 23 05 2...

Page 2: ...t organisation at the workplace i e not being obstacle for a car lift or for high vehicles The appliance works with following fans manufactured by KLIMAWENT S A built on fans FA installed directly at...

Page 3: ...hose assemblies for the ALA U C N reel extractor Type of the hose assembly Hose diameter Weight Hose length Recommended volume flow Flow resistances1 Thermal resistance Application4 Cooperating fans...

Page 4: ...laced the outlet of the extractor to which can be installed a built on radial fan type FA delivery on separate order The outlet of the extractor or of the FA type fan ought to be connected with a rigi...

Page 5: ...motor onto the connection in such a way that the hangers holes in the upper part of the fan are matching the holes in the left framework wall and the hole in the support is suitable to the hole in th...

Page 6: ...teps Fig No 4 Shut off damper with the tensioning line CAUTION the setting of the counting mechanism and the setting of the line tension can be performed after the moment when the spiral spring tensio...

Page 7: ...xhaust Extractor can be installed to the ceiling or by means of brackets to the wall or a supporting column Important is that the reel axis is positioned horizontally For mounting use bolts M12 class...

Page 8: ...mpeller rotation sense ought to be according to the arrow on the fan housing OPERATIONAL USE For safety reasons in order to use the Reel Exhaust Extractor correctly follow subsequent steps 1 Operate t...

Page 9: ...nse noise level and the flow effi ciency is too low MAINTENANCE Any revisions and repair are admissible to be executed by an authorized person Construction of the Reel Exhaust Extractor and of the ext...

Page 10: ...of transport it has to be placed in a way described above in foil and placed in a cardboard package as well as protected from an uncontrolled displacement and overturn During transporting and storage...

Page 11: ...at the product Reel Exhaust Extractor type model ALAN U C N serial number ___________________ year of production ___________________ Meets the requirements of the subsequent European Directives 2006 4...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 12 Reel Exhaust Extractor ALAN U C N 23 05 2019 NOTES...