Klimawent
– the warranty of highest quality at attractive price
2 z 12
Reel Exhaust Extractor
ALAN-U/C-N
23.05.2019
INTRODUCTION
The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of
application, assembly, start-up and operational use of the
ALAN-U/C-N
Reel Exhaust Extractor.
Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction.
With regard to continuity of work carried on improvement of our products, we reserve for
ourselves the revision possibility of the draft and technological changes improving their
functional features and safety.
Construction of
ALAN-U/C-N
meets the requirements of the current state of technology as well as the safety and
health assurances included in:
2006/42/EC Directive
of the European Parliament and of the Council of the 17 May, 2006 on machinery,
amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24);
Additionally, it is in accordance with the subsequent harmonised standards:
EN ISO-12100:2012
Safety of machinery
– General principles of design – Assessment and reduction of hazard
PURPOSE
ALAN-U/C-N
Reel Exhaust Extractors with a spring drive are designed for effective removal of noxious and
hazardous chemical compounds emitted in exhaust gases of vehicles during diagnostics, adjustment, and engine
tests and similar. They eliminate health hazards and risk of life of the operating personnel, provide clean air at the
workplace, thereby providing more safety and comfort. They are used in bus depots, garages and car service
stations.
Simple use, ergonomic and economic solution as well as high capture efficiency
– are their basic advantages.
The extractor can be installed on a wall, under the ceiling and this provides efficient organisation at the workplace,
(i.e. not being obstacle for a car lift or for high vehicles).
The appliance works with following fans manufactured by KLIMAWENT S.A.:
–
built-on fans
FA
– installed directly at the exhaust reel,
–
flange-type fans
WPA-E-N
– installed independently on a separate bracket,
–
roof fans
WPA-D-N
.
RESERVATIONS OF MANUFACTURER
Manufacturer accepts no liability for any consequences following from the operational use that is in
contradiction to the purpose of application.
Operational use with cooperation with an inefficiently functioning extraction fan, as this would result in
overheating and damage of the exhaust hose.
Protect the exhaust hose from mechanical damage and pollution with oils and solid lubricating grease.
Maintenance and any repair can be executed exclusively by an authorised person.
During the use, the vehicle engine can work at maximum rotations for not longer time than 60
seconds
.
During hose winding
– observe that the hose is distributing on the reel evenly, regularly to avoid clenching.
Prior to installing
– check the load carrying capacity of the ceiling / wall, in a place where the unit shall be
installed; unsure setting of mounting bolts could result in uncontrolled device detachment, its damage
and risk to the operator / people in the vicinity.
Installing of any additional elements that are not belonging to the normal device structure (or accessory
set) is not acceptable.
Do not introduce any structural or constructional modifications on the device on
one’s own.
Manufacturer is not responsible for body lacerations, injuries, wounds
– experienced by operator due to
careless use or negligence.
TECHNICAL DATA
Table No.1
Extractor type
Equipped with a
shut-off damper
Maximum
torque
Maximum length of the
exhaust hose
Diameter of the
exhaust hose
Weight
[Nm]
[m]
[mm]
[kg]
ALAN-U/C-8-N
no
50
8
100
125
150
44,5
ALAN/P-U/C-8-N
yes
ALAN-U/C-12-N
no
12
46,5
ALAN/P-U/C-12-N
yes
CAUTION:
1
.
upon selection of the extractor size
– contact KLIMAWENT S.A.
2
.
weight of the extractor is specified without the installed hose