background image

User´s manual - IRIS T / ENTER T 

All work, like installation must be carried out by the qualified person – with professional qualifications and 

expertise in electricity and electrotechnics accordance with law and rules in concrete country.  

Disconnect power supply before any installation or manipulation – preferably with circuit breaker. 

 

1.

 

Remove the cover with a small screwdriver.Install the fan so the service cables will be in lower part  

      of the fan. Place the fan into air duct with suitable diameter. In a prepared place drill a hole for the    
      electric service cable. (Warning! Sharp edges can damage wire insulation!). Install the fan using suitable  
      screws and plugs. 
 

 
 
 
                                                              
 
                                
 
 
 
 
 
 
                                                                                                                      
                                                                                                                          Mounting hole 
 

2.

 

Connect the fan with power supply using the terminal strip. Usually goes from wall electric cable with  

      3 wires, so the blue is directly earthed conductor (N), brown / black is the phase conductor (L – under  
      constant voltage) and third yellow-green is the circuit protective conductor (no need to connect when  
      mounting plastic fan, can be blinded). 
      Install the fan so the service cables will be in lower part of the fan. 

             

     Tubular fans ENTER T, IRIS T has electronics, which you connect directly to power supply 
     (directly earthed conductor –N- and brown / black phase conductor -L - under constant voltage). 

           Into terminal T connect controlled phase wire from on-off switch (standard specification – brown). 
 

 
 
 

 
 
 
                                                                                         
 
 
 
 
 
 
 
 
 
 
 
 
                      Place for service cable            

Directly earthed conductor (N)

   

Controlled phase (T)

     Phase (L) 

 