Klein Tools CL200 Instruction Manual Download Page 1

CUSTOMER SERVICE

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

1-877-775-5346

[email protected]

www.kleintools.com

139560T Rev. 11/13 B

ENGLISH

•  AUTO / MANUAL 

RANGE

•  DATA HOLD

•  3-1/2 DIGIT 

1999 COUNT LCD

•  BACKLIGHT

•  WORKLIGHT

•  TEMPERATURE

ENGLISH

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

400mV

0.1mV

± (0.8% + 2 digits)

4V

0.001V

40V

0.01V

400V

0.1V

600V

1V

± (1.0% + 2 digits)

Overload Protection:

 600V DC / AC

Input Impedance:

 10M

Ω

.

AC Voltage Measurement

Range

Resolution

Accuracy

400mV

0.1mV

± (1.0% + 10 digits)

4V

0.001V

40V

0.01V

400V

0.1V

600V

1V

± (1.2% + 10 digits)

Overload Protection:

 600V DC / AC

Frequency:

 40 to 400Hz

Input Impedance:

 10M

Ω

.

Response:

 Averaging

AC Current Measurement

Range

Resolution

Accuracy

4A

0.001A

± (3.5% + 20 digits) 

 0.5A

4A

0.001A

± (3.0% + 10 digits) > 0.5A

40A

0.01A

± (3.0% + 10 digits) 

400A

0.1A

± (2.5% + 10 digits)

600A

1A

± (1.5% + 5 digits)

Overload Protection:

 720A for 60 sec. max

Frequency:

 50 to 60Hz

Response:

 Averaging

Resistance Measurement

Range

Resolution

Accuracy

400

Ω

0.1

Ω

± (1.2% + 2 digits)

4k

Ω

 

0.001k

Ω

40k

Ω

0.01k

Ω

400k

Ω

0.1k

Ω

4M

Ω

0.001M

Ω

40M

Ω

0.01M

Ω

± (2.0% + 5 digits)

Overload Protection:

 600V DC / AC

Capacitance Measurement

Range

Resolution

Accuracy

50nF

0.01nF

± (3.0% + 10 digits)

500nF

0.1nF

± (3.0% + 5 digits)

5µF

0.001µF

50µF

0.01µF

100µF

0.1µF

Overload Protection:

 600V DC / AC

Frequency Measurement

Range

Resolution

Accuracy

50Hz

0.01Hz

± (0.1% + 3 digits)

500Hz

0.1Hz

5kHz

0.001kHz

50kHz

0.01kHz

100kHz

0.1kHz

Overload Protection: 

600V DC / AC

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (3.0% + 0 digits)

Overload Protection: 

600V DC / AC

Temperature Measurement

Range

Resolution

Accuracy

-4 ˜ 1832°F

1°F

± (3.0% + 3 digits)

-20 ˜ 1000°C

1°C

± (3.0% + 2 digits)

Overload Protection:

 600V DC / AC

Diode Test

Overload Protection

Resolution

Open Circuit Voltage

600V DC / AC

1mV

Appx. 1.5V

Continuity Test

Overload Protection

Resolution

Open Circuit Voltage

600V DC / AC

100m

Ω

Appx. 0.45V

WARRANTY

www.kleintools.com/warranty

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using 

a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of 

time. Do not expose to high temperatures or humidity. After a period of storage 

in extreme conditions exceeding the limits mentioned in the Specifications 

section, allow the instrument to return to normal operating conditions before 

using it.

DISPOSAL / RECYCLE

Caution: 

This symbol indicates that equipment and its accessories 

shall be subject to a separate collection and correct disposal.

Dwg Name: 

CL200-139560TART

  Dwg No: 

139560T 

     

ECO No: 

15429  

Pkg Dwg Ref: 

1650

 

  

Rev: 

B

Color Reference: 

N/A

Instruction Manual

CL

200

600A

600V

CL200 Instruction Manuals - MASTER.indd   1-4

12/16/2013   12:16:18 PM

Summary of Contents for CL200

Page 1: ...verload Protection 600V DC AC Frequency Measurement Range Resolution Accuracy 50Hz 0 01Hz 0 1 3 digits 500Hz 0 1Hz 5kHz 0 001kHz 50kHz 0 01kHz 100kHz 0 1kHz Overload Protection 600V DC AC Duty Cycle Measurement Range Resolution Accuracy 0 1 99 9 0 1 3 0 0 digits Overload Protection 600V DC AC Temperature Measurement Range Resolution Accuracy 4 1832 F 1 F 3 0 3 digits 20 1000 C 1 C 3 0 2 digits Ove...

Page 2: ...ements Do not open the meter to replace batteries while the probes are connected Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose a shock hazard To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless measuring voltage or current shut off and lock out power before measuring resistance or capacitance A...

Page 3: ...ón contra sobrecarga 600 V CD CA Medición de frecuencia Rango Resolución Precisión 50 Hz 0 01 Hz 0 1 3 dígitos 500 Hz 0 1 Hz 5 kHz 0 001 kHz 50 kHz 0 01 kHz 100 kHz 0 1 kHz Protección contra sobrecarga 600 V CD CA Medición de ciclo de servicio Rango Resolución Precisión 0 1 99 9 0 1 3 0 0 dígitos Protección contra sobrecarga 600 V CD CA Medición de temperatura Rango Resolución Precisión 4 1832 F 1...

Page 4: ...realizar las mediciones No abra el multímetro para reemplazar las baterías mientras las sondas están conectadas Proceda con precaución cuando trabaje con voltajes superiores a 60 V CD o 25 V CA RMS Esos voltajes implican un riesgo de descarga Para evitar lecturas falsas que puedan provocar descarga eléctrica reemplace las baterías si aparece el indicador de batería baja A menos que esté midiendo v...

Page 5: ...tion contre la surcharge 600 V c c c a Mesure de fréquence Plage de mesure Résolution Précision 50 Hz 0 01 Hz 0 1 3 chiffres 500 Hz 0 1 Hz 5 kHz 0 001 kHz 50 kHz 0 01 kHz 100 kHz 0 1 kHz Protection contre la surcharge 600 V c c c a Mesure de cycle de service Plage de mesure Résolution Précision 0 1 99 9 0 1 3 0 0 chiffres Protection contre la surcharge 600 V c c c a Mesure de température Plage de ...

Page 6: ...que les sondes sont connectées Faites preuve de prudence lors de mesures sur des circuits de plus de 60 V c c ou de 25 V c a valeur efficace De telles tensions constituent un risque d électrocution Pour éviter les lectures faussées pouvant provoquer une électrocution remplacez les piles lorsque l indicateur de piles faibles apparaît À moins de mesurer la tension ou le courant fermez et verrouillez...

Reviews: