CLEANING

Be sure meter is turned off and wipe with a clean, dry lint-free 

cloth. 

Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when meter is not in use for a prolonged 

period of time. Do not expose to high temperatures or 

humidity. After a period of storage in extreme conditions 

exceeding the limits mentioned in the General Specifications 

section, allow the meter to return to normal operating 

conditions before using.

WARRANTY

DISPOSAL / RECYCLE

 

 

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for 092644692833

Page 1: ...TRUCTION MANUAL 400A AC Auto Ranging Digital Clamp Meter 400A AC Auto Ranging Digital Clamp Meter NON CONTACT VOLTAGE TESTING AUTO RANGING DATA HOLD RANGE HOLD AUDIBLE CONTINUITY ENGLISH CL120 2m CAT...

Page 2: ...ght 11 04 oz 313 g including batteries Calibration Accurate for one year Auto Power Off APO After approx 10 minutes of inactivity Standards IEC EN 61010 1 61010 2 032 61010 2 033 IEC EN 61326 1 61326...

Page 3: ...30 digits 20 00A 10mA 2 0 10 digits 200 0A 100mA 400A 1A Frequency Range 50 to 60Hz Resistance 200 0 0 1 1 2 5 digits 2 000K 1 1 2 3 digits 20 00k 10 200 0k 100 2 000M 1k 20 00M 10k 2 0 5 digits Maxim...

Page 4: ...alse readings that can lead to electrical shock replace batteries when a low battery indicator appears Do not attempt to measure resistance or continuity on a live circuit Always adhere to local and n...

Page 5: ...nt LCD display 8 MAX Maximum button 2 Function selector switch 9 Data Hold button 3 Clamp 10 Clamp trigger 4 COM jack 11 Arrow markings 5 V jack 12 NCV Button 6 Backlight button 13 NCV Light 7 RANGE b...

Page 6: ...t measurement range is deactivated on the LCD Repeatedly press the RANGE button 7 to cycle through the available ranges stopping once the desired range is reached 2 To return to auto ranging mode pres...

Page 7: ...NT LOCATIONS Ensure the test lead shield is pressed firmly in place Failure to use the CATIII CATIV shield increases arc flash risk TESTING IN CAT II MEASUREMENT LOCATIONS CAT III CAT IV shields may b...

Page 8: ...ire passes perpendicularly through the center of the clamp in line with the arrow markings 11 To measure current 1 Rotate the Function Selector switch 2 to the 200 400 A setting 2 Place clamp around w...

Page 9: ...the test leads are being applied to the circuit in reverse Swap the position of the leads to correct this NOTE When in a voltage setting and the test leads are open readings of order mV may appear on...

Page 10: ...a failed resistor is under test the display will indicate O L This is normal DO NOT attempt to measure resistance on a live circuit CONTINUITY 1 Insert RED test lead into V jack 5 and BLACK test lead...

Page 11: ...eplace 3 x AAA batteries note proper polarity 3 Replace battery cover and fasten screw securely To avoid risk of electric shock disconnect leads from any voltage source before removing battery door To...

Page 12: ...not in use for a prolonged period of time Do not expose to high temperatures or humidity After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications s...

Reviews: