background image

 

_______________________________________________________________________________________________________________________________

 

Klaxon Signals Ltd.

   Wrigley Street, Oldham, Lancashire UK OL4 1HW                    [email protected]            Tel: +44 (0)161 287 5555 

                                                                                                                                        www.klaxonsignals.com               Fax: +44 (0)161 287 5511 

Document No. Klaxon Syrex IS-XN       Issue:  A            11-11-05               Sheet 1 of  3

 

 

 

 

 

 

                 

 

 

 

 

 

 

 

 

1.  INTRODUCTION 

The  Syrex  IS-XN  is  an  ATEX  certified  intrinsically  safe 

beacon  which  will  produce  a  visual  warning  in  a  hazardous 

area.      Red,  Amber,  Green  and  Blue  output  models  are 

available. 

   

 

2. DESCRIPTION 

The  device  will  start  to  flash  when  power  is  applied  to 

ter and -. The beacon has two flash rates one double 

flash  per  second  and  two  double  flashes  per  second.  The 

flash  rate  is  selected  by  setting  an  internal  pin  header.  The 

unit is factory set to produce two double flashes per second. 

 

3. SUPPLY VOLTAGE 

The Syrex IS-XN beacon has been designed to operate in a 

hazardous  area  via  a  28V  300  ohm  ATEX  certified  Zener 

barrier  or  galvanic  isolator.  The  beacon  may  be  tested  or 

used  in  safe  areas  without  a  Zener  barrier  or  galvanic 

isolator, but at supply voltages above 16V the internal current 

limit will function  and the brightness may  be reduced.    The 

beacon should not be continuously operated without a barrier 

or isolator with a supply voltage greater than 16V.  

 

 

4. INTRINSIC SAFETY CERTIFICATION 

 

4.1 ATEX certificate 

The  Syrex  IS-XN  beacon  complies  with  the  following 

standards:-  

 

EN50014 : 1997 + A1 and A2 

EN50020 : 2002 

EN50284 : 1999 

 

 

 

The  EC-Type  Examination  Certificate  SIRA  05ATEX2269X 

has  been  issued  by  the  Notified  Body  Sira.  This  confirms 

compliance  with  the  European  ATEX  Directive  94/9/EC  for 

Group  II,  Category  1G  equipment.    The  beacon  carries  the 

Community Mark and subject to local codes of practice, may 

be installed in any of the EEA member countries. 

 

 

 

 

 

 

 

This  instruction  sheet  describes  installations  which  conform 

to  BS  EN  60079:Part14:2003  Electrical  Installation  in 

Hazardous  Areas.    When  designing  systems  for  installation 

outside  the  UK,  the  local  Code  of  Practice  should  be 

consulted. 

 

 

1) The certification marking is as follows:  

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

Syrex IS-XN Beacon

II 1G   EEx ia IIC T4 (-40ºC <=Ta<= +60°C)

Ui = 28V   Pi = 1.2W

                  Ci = 0   Li = 0

0518

SIRA 05ATEX2269X

Year / Serial No. 05 / 6MB000001

Klaxon Signals Ltd.

Oldham OL4 1HW.  UK.

www.klaxonsignals.com

 

2)  The  equipment  may  be  used  in  zones  0,  1  and  2 

with  flammable  gases  and  vapours  with  apparatus 

groups  IIA,  IIB  &  IIC  and  with  temperature  classes 

T1, T2, T3 and T4. 

3)  The  equipment  is  only  certified  for  use  in  ambient 

temperatures  in  the  range  -40

o

C  to  +60

o

C  and 

should not be used outside this range. 

4)  The  certificate  number  has  an  ‘X’  suffix,  which 

indicates  that  the  certificate  contains  one  of  more 

special  conditions  for  safe  use.  Those  installing  or 

inspecting the equipment should refer to this section 

of the certificate. 

5)  The equipment has not been assessed as a safety-

related  device  (as  referred  to  by  Directive  94/9/EC 

Annex II, clause 1.5). 

6)  Installation of this equipment shall be carried out by 

suitably-trained personnel in accordance with the 

applicable code of practice. 

7)  Repair of this equipment shall only be carried out by 

the manufacturer or in accordance with the 

applicable code of practice. 

8)  The certification of this equipment relies on the 

following materials used in its construction: 

 

 

 

Enclosure:

 

ABS Plastic 

 

 

Lens: 

 

Polycarbonate

 

 

 

 

If the equipment is likely to come into contact with 

aggressive substances, then it is the responsibility of 

the user to take suitable precautions that prevent it 

from being adversely affected, thus ensuring that the 

type of protection is not compromised. 

 

“Aggressive substances” - e.g. acidic liquids or 

gases that may attack metals, or solvents that may 

affect polymeric materials. 

 

“Suitable precautions” - e.g. regular checks as part 

of routine inspections or establishing from the 

material’s data sheet that it is resistant to specific 

chemicals. 

The Syrex IS-XN beacon is CE marked for 

compliance with the European Explosive 

Atmospheres Directive 94/9/EC and the 

European EMC Directive 89/336/EEC 

II 1G EEx ia IIC T4 (-40ºC <= Ta <= +60ºC) 