53
Midi Sysex Data
Notes
$nn = Hexadecimal Data - Decimal data is in Brackets e.g. $0a (10)
Sysex Header
$f0
Sysex Start
$00 $21 $16
Kiwitechnics Manufacturers ID
$60
Kiwitechnics Family ID
$07
Kiwitechnics Kiwi-30 ID
xx
Command ID (see table 1.0)
$01
=
Request Global Dump
$02
=
Transmit/Receive Global Dump
$03
=
Request Tone Edit Buffer Dump
$04
=
Transmit/Receive Tone Edit Buffer Dump
$05
=
Request Tone Dump
$06
=
Transmit/Receive Tone Dump
$09
=
Request Seq Dump
$0a
=
Transmit/Receive Seq Dump
$0d
=
Request Tone Parameter
$0e
=
Transmit/Receive Tone Parameter
$0f
=
Request Global Parameter
$10
=
Transmit/Receive Global Parameter
Data
Depending on command type (see table 1.0)
$f7
Sysex Footer
WARNING! Sysex dumps have the ability to put non valid settings into memory and few checks are made for validity. If the Kiwi-30
becomes unusable due to non valid data you may need to do a full restore of the Kiwi-30 which will lose all saved memory.
www.kiwitechnics.com